The power cable should not be in contact with the pump or
pipeline.
The voltage value of the mains must be in between the limits
given in Table 5.2.
It is recommended to use a residual-current device (RCD) to protect the user
and the pump. The RCD should be chosen according to the nominal voltage
and current of the pump and it should be able to trip on high frequency leakages
(type B) (The tripping current should be lower than 3.5mA according to the EN
60335).
7. DISPLAY AND SETTINGS
The display of the Optima pumps has two text rows, three LEDs and five control
buttons. See Figure 7.1.