39
4 Setting Up (Oxy2, Pressure transmitter and Dive Computer)
II Uwatec
®
Aladin
®
Air Z O
2
English
II
Oxy2 and dive computer must be in physical contact during all the pairing
procedure.
3. Bridge the Oxy2 contacts E and B (switching on, sensor capacity check).
4. The dive computer shows after a short time a flashing <PAIr> in the lower
display.
5. In order to confirm the pairing, the B- and E-contacts have to be bridged within
5 sec. A bleep confirms the input and the <PAIr>-display still remains. The
computer and Oxy2 must remain in physical contact until the confirmation has
been done.
6. Oxygen data is displayed after approximately 10 seconds.
7. In case of faulty pairing, the display <FAIL> appears instead of <PAIr>. In that
case, the pairing procedure has to be repeated.
tank data
tank data
tank data
bar
%
tank data
10 sec