38
4 Setting Up (Oxy2, Pressure transmitter and Dive Computer)
II Uwatec
®
Aladin
®
Air Z O
2
4.4 How to check that the computer is paired correctly:
Oxy2 and dive computer
1. Switch on the Oxy2 and the dive computer.
2. Compare the lower part of the dive computer with the Oxy2 display. Pairing has
been carried out correctly if the oxygen data is displayed within approximately
10 to 15 seconds. This delay is because of the start-up transmission procedure
and a data plausibility check.
Pressure transmitter and dive computer
1. Switch on the computer manually (B and E) and bring it into the transmitting
range of the transmitter.
2. Open the tank valve while the regulator is closed. The transmitter switches on
automatically.
3. Check the display in the lower part of Aladin
®
Air Z O
2
: Pairing has been carried
out correctly if the pressure is displayed within approximately 10 to 15 seconds.
If there is no pairing of Oxy2 and computer or pressure transmitter and
computer, <---> is displayed instead of oxygen data or the pressure. In that
case, Oxy2 or pressure transmitter and computer have to be paired.
4.5 Pairing of Oxy2 and dive computer:
1. Switch on the Oxy2 . Make sure that the turn-
able switch is in position „RUN“.
2. Switch on the dive computer manually (B and
E) and move it into the position shown below.
tank data
bar
%
tank data
bar
tank data
pairing with Oxy2
pairing with pressure
transmitter
no pairing