STEP 1
Determine where ALL200 will mount on ceiling joists. ALL200 must be installed level, in an accessible
location directly above chandelier.
https://youtu.be/yLV_1HaU56Y
Never mount the ALL200 off plane or unlevel in a standard installation. This could cause the chandelier
to fall, which could cause death, personal injury, and/or property damage. The winch cable must hang
plumb through the center of the top contact plate on the ceiling box.
Never install the ALL200 where the ceiling height exceeds five feet less than the exact length of winch
cable. For example, if the ALL200 is equipped with a 35ft. cable, do not install the ALL200 in a ceiling
that is greater than 30ft. This could cause the cable to become reverse wrapped on the winch. An
ALL200 installed with a reverse wrapped cable could cause the chandelier to fall, which could cause
death, personal injury, and/or property damage. Winch cable length can be found on the ALL200
product sticker, shipping box and the front page of these installation instructions.
STEP 2
After turning off power, remove and discard existing electrical box if present in ceiling. Only use ceiling box
provided with ALL200. See Diagram A.
Never remove an existing ceiling box while the power is connected. Electricity could cause death,
personal injury, and/or property damage.
STEP 3
Cut a 4 ½” hole in ceiling for ceiling box. If you removed an existing ceiling box, existing hole may need to
be enlarged.
STEP 4
Attach conduit assembly to 3/4” conduit connector mounted below pulley. Once completely inserted,
tighten set screw on conduit connector. The minimum measurement from the bottom of the ceiling box up
to the bottom of the channel strut is 8”. Additional framing may be required to add depth and maintain
adjustablility of the conduit assembly. See Diagram A.
https://youtu.be/JghN8ECvTz4
Never attach or adjust the conduit assembly improperly. This could interfere with the automatic shutoff
system and could cause the chandelier to fall, which could cause death, personal injury, and/or property
damage.
ALL200 Ceiling Box
Telescopic Conduit Assembly
3/4” Conduit Connector
Diagram A
8” Minimum
13” Maximum