ALL200 TROUBLESHOOTING GUIDE
cont.
1. Confirm ALL200 is at the CEILING POSITION. If not, use the controller to operate the ALL200 to
the CEILING POSITION. Chandelier will only light at the CEILING POSITION. If operated to the
CEILING POSITION and the chandelier will still not light, proceed to step 2.
2. Confirm light and motor switch in the square box are turned on. The square box is mounted on the
chassis plate of the ALL200, right in front of the control board. If it was found in the off position, flip it to
the on position and test the chandelier. If chandelier still does not light, proceed to step 3.
3. Turn the motor and light switch in the square box to the off position. Confirm light fuse is good. The
light fuse is held to the control board by fuse clips and is located right in front of the light relay. Remove
and perform a continuity test on the light fuse. If the fuse reads continuity, place it back in the fuse clips.
If it does not read continuity, it must be replaced with a new, 15 amp, fast blow fuse. If the ALL200 was
equipped with a 2200 watt upgrade package, replace with a new, 20 amp, fast blow fuse. Turn the motor
and light switch in the square box to the on position, and test the chandelier. If the chandelier still does not
light, proceed to step 4.
4. From where the ALL200 is installed, call Aladdin Light Lift technical support Monday through Friday
during normal business hours at (877) 287-4601. A voltage meter will be needed to further test the
ALL200.
SYMPTOM: ALL200 WILL NOT SHUT OFF PROPERLY AT CEILING POSITION:
Discontinue use immediately and contact Aladdin Light Lift at (877) 287-4601.
After all troubleshooting is complete, replace control board cover.
WHITE
OR
PURPLE
GREEN OR ORANGE
RED OR BROWN
Replace with same type (ABC)
same amp, fast acting fuse:
ALL200-15A,250V ALL700-20A,250V
ALL300-15A,250V ALL1000-20A,250V
W
hite or Pu
rp
le (C
OMMON)
Green or Orange (NO)
Red or Brown (NC)
Replace with same type (GDC)
same amp, slow blow fuse:
ALL200-1.6A,250V ALL700-1.6A,250V
ALL300-1A,250V ALL1000-1.6A,250V
NOTE:
When installing a new circuit board, please see the
key below for the wiring of the limit switch wire to
the new circuit board:
COM = WHITE OR PURPLE WIRE
NO = GREEN OR ORANGE WIRE
NC = RED OR BROWN WIRE
Limit switches must be wired as seen in diagram below. If not wired correctly, this could
cause the chandelier to fall, which could cause death, personal injury, and/or property
damage.