GB
48
493516_a
Help in case of malfunction
Display
Fault
Fault description
Fault rectification
Err 07
Mower mecha-
nism contact
switch
ECU detects incorrect sta-
tus of the mower mecha-
nism output.
1. Switch the ignition off and back on
again (position 1)
■
Self-diagnosis, if necessary, auto-
matic deletion of the fault*,
■
otherwise contact Service
Err 08
Start relay
ECU detects incorrect sta-
tus of the start relay output.
1. Switch the ignition off and back on
again (position 1)
■
Self-diagnosis, if necessary, auto-
matic deletion of the fault*,
■
otherwise contact Service
Err 09
Solenoid valve
ECU detects incorrect sta-
tus of the engine solenoid
valve output.
1. Switch the ignition off and back on
again (position 1)
■
Self-diagnosis, if necessary, auto-
matic deletion of the fault*,
■
otherwise contact Service
Err 10
Ignition coil
ECU detects incorrect sta-
tus of the ignition coil out-
put.
1. Switch the ignition off and back on
again (position 1)
■
Self-diagnosis, if necessary, auto-
matic deletion of the fault*,
■
otherwise contact Service
Err 11
Internal supply
voltage
ECU detects incorrect sta-
tus of the internal supply
voltage output.
1. Switch the ignition off and back on
again (position 1)
■
Self-diagnosis, if necessary, auto-
matic deletion of the fault*,
■
otherwise contact Service
Err 12
Internal supply
voltage monitor-
ing
ECU detects incorrect sta-
tus of the internal supply
voltage monitoring.
1. Switch the ignition off and back on
again (position 1)
■
Self-diagnosis, if necessary, auto-
matic deletion of the fault*,
■
otherwise contact Service
* : * The display goes out for about 4 seconds.
**: Delete the error by pressing the R key (03/13).