Removal of AL-KO Sensabrake Mouse gain slide
and fitting of a cover to disallow adjustment.
FIGURE 1
FIGURE 2
FIGURE 3
QUALITY FOR LIFE
Figure 4
Figure 5
Figure 6
5. Very carefully extract the adjustment arm from the trim pot. The adjustment arm
has a hexagonal shaft which fits into the trim pot and may require gentle pressure
using small pliers to remove it. Any rotational movement of the adjusting arm will
alter the previously set brake performance setting. Remove the mouse gain slide.
(Fig 4)
6. Reassemble the mouse top and refit the 4 screws, leaving the gain slide and
adjustment arm out of the assembly.
(Fig 5)
7. Fit AL-KO part number 350258 Cover to the front of the Mouse into the slot
previously occupied by the gain slide and secure using fast acting adhesive / glue
(Fig 6)