AL-KO Orion TC 250 Operating Instructions Manual Download Page 9

9

DANGER

This symbol draws your attention to work pro-
cesses or operating procedures that have to be
carefully observed in order to prevent serious injury
to the user or another person.

CAUTION

This symbol draws your attention to information
you need to ensure that your pump is not damaged
due to improper or careless use.

PLEASE NOTE

The information symbol draws your attention to
essential technical requirements.

F

OR

 Y

OUR

 S

AFETY

I

NTRODUCTION

Please read the operating instructions carefully
before you use the submersible pump to prevent
accidents and ensure the trouble-free operation
of the pump.

Make sure you keep the instructions at hand for
quick reference. If you resell your pump or give it
to another user, please include these instructions
in the sale or the gift.

The following symbols are used in the instructions:

GB

The submersible pump may not be used for
any other than its designated use. Before

putting the pump into operation, make sure that
– the submersible pump, the electric cable and

the plug are not worn or damaged and

– nobody is near, touching or in the liquid to be

pumped.

Do not operate the submersible pump if it is
damaged. Necessary repairs must be carried

out in a qualified AL-KO service centre.

Never use the electric cable to lift, carry or
attach the submersible pump to another

object. Do not pull on the cable when unplugging
the pump.

Make sure that the pump is unplugged before
beginning any maintenance, repair or

cleaning work. In the event of a malfunction,
immediately unplug the pump. Make sure that the
plug does not get wet.

Do not attempt to make any changes or
modifications to the submersible pump by

yourself. You may endanger your life or invalidate
the warranty.

U

SE

Designated use
The submersible pump is designed for home use
in your house or garden. Please observe the
technical data given in the instructions before
putting the pump into operation.
Your submersible pump has been designed for use
in the following applications:
– emptying your cellar or house after a flood,
– emptying containers or pumping liquid from one

container into another,

– pumping water from wells,
– aerating garden ponds or artificial brooks and

streams

The submersible pump is designed to pump only
the following liquids:
– clear water,
– rain water,
– chlorine water (pool water),
– water for domestic use.

The submersible pump may only be connect-
ed to an electrical device which is compliant

with  DIN/VDE 0100, Parts 737, 738 and 702
(swimming pools). Make sure that fuse protection
in the form of a 10 A automatic cut-out and a fault
current guard circuit with a nominal fault current of
10/30 mA is installed.

The supply voltage and current specified on
the type plate must be identical with the

voltage and current of your electrical system.

If you need to connect your pump to an
extension cord, make sure that the cable is

3 x 1.5 mm

2

, that it corresponds to type H07RN-F

and is compliant with DIN 57282/57245. The
connector must be splash-proof. Cable drums
must be completely unwound.

The submersible pump may not be operated
by anyone

– who has not read or does not fully understand

the operating manual or

– is under the age of 16.

Summary of Contents for Orion TC 250

Page 1: ...WWW al ko com 547 194 abcdef 2001 ORION TC 250 D GB...

Page 2: ...2 Inhaltsverzeichnis Seite Bildteil 3 Bedienungsanleitung 4 8 D Table of Contents Page Illustrations 3 Operating Instructions 9 13 GB...

Page 3: ...A B C 1 2 3 4 5 6 7 8 min 530 mm min 450 x 450 mm START STOP Q 1 2 3 4 5 6 7 8 9 20 40 60 80 100 120 140 160 180 200 220 240 Hft l h 1 Hm 10 20 29 5 m3 h 1 2 2 4 3 6 4 8 6 7 2 8 4 9 6 10 8 11 12 2 13...

Page 4: ...n werden von Personen die die Bedienungsanleitung nicht gelesen und verstanden haben Kindern und Jugendlichen unter 16 Jahren Die Tauchpumpe darf nur bestimmungs gem verwendet werden Stellen Sie vor G...

Page 5: ...hlauchdurch messers erreicht Wickeln Sie das Anschlusskabel ganz ab Stellen Sie sicher dass elektrische Steck verbindungen im berflutungssicheren Bereich angebracht sind Tauchen Sie die Pumpe langsam...

Page 6: ...das Ger t vom Netz zu trennen und gegen Wiedereinschalten zu sichern Reinigungsarbeiten Nach F rderung von chlorhaltigem Schwimm badwasser oder Fl ssigkeiten die R ckst nde hinterlassen muss die Pump...

Page 7: ...merschalter schaltet nicht bei anstei gendem Wasserstand Pumpe an AL KO Service schicken Tauchpumpe l uft aber f rdert nicht Luft im Pumpengeh use Saugseitige Verstopfung Druckleitung geschlossen Druc...

Page 8: ...Landes in dem das Ger t gekauft wurde Unsere Garantiezusage gilt nur bei Sachgem er Behandlung des Ger tes Beachtung der Bedienungsanleitung Verwendung von Original Ersatzteilen Verbrennungsmotoren F...

Page 9: ...the event of a malfunction immediately unplug the pump Make sure that the plug does not get wet Do not attempt to make any changes or modifications to the submersible pump by yourself You may endanger...

Page 10: ...e g installation of an alarm or a back up pump to ensure that flooding will not occur if the pump should mal function Make sure that the pump does not run on a blocked or closed pressure hose Prohibi...

Page 11: ...ns in an upright position Plub in the electric cable The pump will automa tically switch on and pump out any remaining liquid While pumping out remaining liquid make sure to keep the pump under observ...

Page 12: ...s switched off No power Have a qualified electrician check the power supply Air is trapped in the pump housing Tilt the pump to let the trapped air out Suction slots are blocked Remove blockage and cl...

Page 13: ...he machine was purchased The guarantee ist only valid under the following conditions The machine has been treated properly The operation instructions have been followed Genuine spare parts have been u...

Page 14: ...67 745 33 61 SK AL KO Kober Slovakia Spol s r o Tel 421 2 4341 2642 Fax 421 2 4341 2532 PL AL KO Kober sp z o o Tel 48 61 86 78 532 Fax 48 61 86 78 532 RUS AL KO System GmbH Tel 7 095 168 87 16 Fax 7...