Service Menu
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
16
7.2.5 Additional
Fig. 7.8 Dialog "Additional Settings"
The additional features include:
–
Cursor Settings
o
On
– pointer is always visible
o
Off
– pointer is invisible
o
Auto
– pointer becomes invisible if the display is not touched within 10 sec-
onds
–
Display Rotation
Image on the display can be rotated 90° counterclockwise.
–
Devices Info
Information about the memory usage of the PLC flash memory (ROM), the con-
nected USB mass storage device and SD card
The memory devices are scanned every 10 seconds.
–
Remove
Safely remove mass storage device
The function is available when a mass storage device is connected.
–
Format
Format mass storage device to FAT32
The function is available when a mass storage device is connected.
Use the
Close
key to exit the dialog.
7.3 Factory settings
IP address
10.0.6.10
SubnetMask
255.255.0.0
Gateway
10.0.6.1
COM2, COM3
RS485
Use the
Exit
key to exit the configuration dialog.
Use the
Reboot
key to restart PLC.
7.4 CODESYS project update
The CODESYS project can be updated using a USB mass storage device. To transfer a
new CODESYS project to the PLC the following steps must be taken: