8.) Setting the fan strength (air circulation) 
 

Press the Speed button         in succession for the desired setting. The unit has three fan speeds: 
 
 

 

 

Level 1 

= Weak fan strength (air circulation) 

 
 

 

 

Level 2 

= Medium fan strength (air circulation) 

 

 

 

 

Level 3 

= Strong fan power (air circulation)

 

 
 

9.) Night operation / night mode 
 

Press the speed button         permanently for approx. 3-5 seconds. This switches off the touch panel display and 
the unit jumps to an extremely low-noise fan strength !  
To cancel the night mode again, simply press the button area of the touch panel display again. 
 
 

10.) Timer (timer) 

 
Press the timing button          for approx. 3 seconds until zero (0) starts flashing in the display field. Now you can 
select a value between 0 - 12 hours by pressing repeatedly. After you have selected your desired value, wait for 
approx. 5 seconds until you hear an acknowledgement tone and the display field shows the current temperature 
and humidity value again. Now the remaining time is stored and the air purifier switches off automatically after this 
time has elapsed. 
The remaining time is displayed alternately with the current temperature and the humidity value. In addition, you 
can also display the remaining time by briefly pressing the timing button. 
 
To reset the remaining running time, simply press the timing button continuously for approx. 3 seconds until the 
acknowledgement tone sounds. This switches off (zeroes) the remaining running time and the air purifier works in 
continuous operation again. 
 

 
11.) Filter change indicator 
 

The air purifier has a filter change indicator. 
 
The display is always lit by default, after an active runtime (operating time) of 1,440 hours, the left symbol starts 
flashing and recommends that you now change the combi-filter (activated carbon and catalyst filter). 
After an active runtime (operating time) of 2,880 hours, the right-hand symbol starts flashing and recommends that 
you now change the HEPA/ULPA filter. 
Note: The filter change indicator is time-controlled and depending on the type of use of the air purifier, it may be 
necessary to replace the filters earlier (before the filter change indicator is triggered) ! 
 
After you have replaced the filters, press the reset button         permanently until you hear a long acknowledgement 
tone. Now the flashing filter change indicator is reset and the internal filter runtime count starts again. 
 
 

12.) Cleaning & Storage 
 

Please always disconnect the mains plug first and allow the air purifier to drain completely before carrying out any 
cleaning activities on your unit ! 
 
 
 
 
 
 
 

Summary of Contents for 4260196719407

Page 1: ...o ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the appliance meets your expectations If despite the greatest possible care the...

Page 2: ...NVENTORY e g in wallpaper carpets upholstery textiles Air sensor optionally switchable Automatically measures the air quality If the determined air quality is good the air purifier automatically switc...

Page 3: ...recommended voltage for operating the unit Make sure that the power cable is unfolded untied before connecting it to the socket Make sure that the plug is cleanly and properly connected to the socket...

Page 4: ...lay Remote control receiver Filter Change display Operating buttons Settings Operating mode Speed Air circulation Timing Timer Air quality Display Air circulation Level Operating buttons Reset Reset A...

Page 5: ...rol The filter compartment diagram 1 Prefilter 2 HEPA ULPA filter 3 Combi filter active carbon catalyst 4 UV lamp 5 Air purifier body 5 4 3 2 1 On Off button Sensor Auto button On Off button Ozone On...

Page 6: ...ULPA filter 3 Now close the lateral Filter compartment cover again 1 Open the side filter compartment cover Then remove all filters 2 Grasp the UV lamp and turn them by 90 Now it can be pulled out 3...

Page 7: ...n and automatically starts measuring the air quality There are 4 possible results of the detected air quality see diagram below Please note that the proper air sensor function is only available after...

Page 8: ...nger operating fluctuations may occur from time to time because the air sensor probe is exposed to the draught Reset of the PM value air sensor After prolonged use of the air sensor traces of particle...

Page 9: ...e humidity value In addition you can also display the remaining time by briefly pressing the timing button To reset the remaining running time simply press the timing button continuously for approx 3...

Page 10: ...display as well as via the supplied remote control A button cell CR2032 3V is required to operate the remote control Notes on UV light 1 The UV lamp normally has a service life of approx 4 000 8 000...

Page 11: ...it can take a considerable time until this inventory releases the odours again 2 Please make sure that the air sensor function Auto is not used when the air purifier is in a draught e g between two o...

Page 12: ...rect mains voltage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air purifier has been tested and itself and or parts thereof have been manufac...

Reviews: