background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 
 
 

Troubleshooting: 
 

The unit ices up 
 
At cold temperatures or during long periods of continuous operation, the unit may freeze up despite the defrost 
sensor. In this case, we recommend that you manually defrost the unit by switching it off and then only operate it 
with a target humidity value of 60% r.l. for the time being, or warm up the room a little. The target humidity value 
can then be gradually lowered each day (e.g. 50%, then 40%, etc.).  
 
The unit does not dehumidify enough 
 
Please remember that the primary aim is not to gain as much condensation water as possible, but to dry and/or 
keep dry the room air or ceilings, walls and inventory ! 
 
Furthermore, bear in mind that the building dryer can only remove moisture from the air and only indirectly from 
materials (screed/plaster). Depending on the condition of the ceilings, walls and fixtures, it can take several weeks 
before they release the stored moisture back into the air! For this reason, we also recommend that if you use your 
own humidity meter (hygrometer), you place it as freely as possible and somewhat away from walls and ceilings, 
because otherwise the determined humidity value of the room air will be falsified!!! 
 
As with all building dryers, the dehumidification performance is decisively influenced by the following factors: 
A) Humidity content of the room air and B) Heat/temperature in the room.  
For safety's sake, here is an approximate dehumidification table for DURABLE OPERATION: 
 

30 degrees 

and 80% r.h. = approx. 120 litres 

 

and at 60% r.h. = approx. 60 litres 

20 degrees 

and 80% r.h. = approx. 60 litres 

 

and at 60% r.h. = approx. 35 litres 

15 degrees 

and 80% r.h. = approx. 45 litres 

 

and at 60% r.h. = approx. 25 litres 

10 degrees 

and 80% r.h. = approx. 25 litres 

 

and at 60% r.h. = approx. 17 litres 

 
All figures are approximate per day (fluctuation tolerance) when measured directly at the unit inlet and of course 
these values only apply if the temperature and moisture content remain constant! 

 
 

Other: 

 
Warranty statement: 

 
Notwithstanding the statutory warranty claims, the manufacturer grants a warranty in accordance with the laws of 
your country, but at least 1 year (in Germany 2 years for private individuals). The warranty begins on the date of 
sale of the appliance to the end user. 
The warranty only covers defects that are due to material or manufacturing faults. 
are. 
Warranty repairs may only be carried out by an authorised customer service. To 
To make your warranty claim, please enclose the original sales receipt (with date of sale). 
Excluded from the guarantee are: 
 

Normal wear 

Improper applications, such as overloading the appliance or non-approved accessories. 

Damage due to external influences, use of force or foreign objects 

Damage caused by non-observance of the operating instructions, e.g. connection to an incorrect mains voltage 
or non-observance of the assembly instructions. 

Completely or partially dismantled units 

 

 
 
 
 
 

Summary of Contents for 4260196710046

Page 1: ...improper transport can sometimes occur despite careful instructions on the carton We therefore ask you to leave it upright for at least 1 hour before using it for the first time so that the cooling li...

Page 2: ...the wall to avoid possible overheating of the unit Do not use in airtight rooms Only qualified personnel or electricians are allowed to open the unit or carry out repairs Make sure that no moisture g...

Page 3: ...leak cannot be detected immediately by an emerging odour If refrigerant leaks it may ignite or explode especially in poorly ventilated rooms in conjunction with high heat sparks or flames Make sure th...

Page 4: ...ny www AKTOBIS de Email Info Aktobis de Compressor light Defrost light Description of the unit parts Control element ON OFF SWITCH Operating hours counter Humidity display Increase button the target m...

Page 5: ...h on process is delayed by approx 3 minutes Compressor light flashes during this time 2 Operating procedure After the building dryer is properly connected to the socket the backlight of the display pa...

Page 6: ...ter or similar 6 2 Cleaning the air filter screen and the cooling fins The air filter screen at the front of the air intake filters lint hair and coarse construction dust ensuring that this dirt is no...

Page 7: ...perature This can lead to greatly increased room temperatures in smaller and well insulated rooms this is quite normal For an effective and economical dehumidification operation please close all doors...

Page 8: ...midity content of the room air and B Heat temperature in the room For safety s sake here is an approximate dehumidification table for DURABLE OPERATION 30 degrees and 80 r h approx 120 litres and at 6...

Page 9: ...EN 55014 2 2015 EN IEC 61000 3 2 2019 EN IEC 61000 3 11 2019 Correct disposal of this product Within the EU this symbol indicates that this product should not be disposed of with household waste Old a...

Reviews: