Important operating and safety instructions regarding the refrigerant R454C in this unit: 

(Read these instructions carefully and observe them before using the unit !) 

 

 

The unit operates with the refrigerant R454C. This refrigerant is flammable and explosive if the safety 
instructions are not observed! 

 

The refrigerant R454C complies with the European environmental directives ! 

 

The unit should not be stored or operated in a room with burning/heating appliances or open fire ! 

 

Protect the unit and especially the parts installed inside from damage or flames/heat ! 

 

Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an 
emerging odour ! 

 

If refrigerant leaks, it may ignite or explode, especially in poorly ventilated rooms in conjunction with high heat, 
sparks or flames ! 

 

Make sure that the outlet of the exhaust air is always ensured and not obstructed by other objects ! 

 

Set-up, operation and storage of the unit should take place in a room with a minimum size of 4 

m2 !

 

 

Pack the unit carefully when you are no longer using it and protect it from damage! 

 

When cleaning, proceed strictly according to the manufacturer's instructions and do not use any additional heat 
sources to possibly accelerate the defrosting process of the appliance ! 

 

Never work on the cooling circuit or parts containing refrigerant yourself ! 

 
 
 

This unit has parts that must not be replaced or repaired ! 

 

The refrigerant cannot be renewed or replaced ! 

 

Do not carry out any independent repairs or modifications to your unit ! 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 4260196710046

Page 1: ...improper transport can sometimes occur despite careful instructions on the carton We therefore ask you to leave it upright for at least 1 hour before using it for the first time so that the cooling li...

Page 2: ...the wall to avoid possible overheating of the unit Do not use in airtight rooms Only qualified personnel or electricians are allowed to open the unit or carry out repairs Make sure that no moisture g...

Page 3: ...leak cannot be detected immediately by an emerging odour If refrigerant leaks it may ignite or explode especially in poorly ventilated rooms in conjunction with high heat sparks or flames Make sure th...

Page 4: ...ny www AKTOBIS de Email Info Aktobis de Compressor light Defrost light Description of the unit parts Control element ON OFF SWITCH Operating hours counter Humidity display Increase button the target m...

Page 5: ...h on process is delayed by approx 3 minutes Compressor light flashes during this time 2 Operating procedure After the building dryer is properly connected to the socket the backlight of the display pa...

Page 6: ...ter or similar 6 2 Cleaning the air filter screen and the cooling fins The air filter screen at the front of the air intake filters lint hair and coarse construction dust ensuring that this dirt is no...

Page 7: ...perature This can lead to greatly increased room temperatures in smaller and well insulated rooms this is quite normal For an effective and economical dehumidification operation please close all doors...

Page 8: ...midity content of the room air and B Heat temperature in the room For safety s sake here is an approximate dehumidification table for DURABLE OPERATION 30 degrees and 80 r h approx 120 litres and at 6...

Page 9: ...EN 55014 2 2015 EN IEC 61000 3 2 2019 EN IEC 61000 3 11 2019 Correct disposal of this product Within the EU this symbol indicates that this product should not be disposed of with household waste Old a...

Reviews: