Aktakom ATH-2235 User Manual Download Page 6

www.tmatlantic.com 

6

 

(14) Master constant voltage adjustment: adjusting master output 

voltage. 

(15) Fixed 5V output terminal (+): connecting the positive terminal of 

load. 

(16) Fixed 5V output terminal (-): connecting the negative terminal of 

load. 

(17) Master constant current adjustment: adjusting master output 

current value (adjusting the current-limit protection point). 

(18) Master output terminal (+): connecting the positive terminal of 

load. 

(19) Case ground: connecting the case to ground. 

(20) Master output terminal (-): connecting the negative terminal of 

load. 

(21) Slave output terminal (+): connecting the positive terminal of 

load. 

(22) Case ground: connecting the case to ground. 

(23) Slave output terminal (-): connecting the negative terminal of 

load. 

2.2 Operating method 

2.2.1 Independence use of two adjustable output 

2.2.1.1 Set (7) and (9) switch to spring out position. 

2.2.1.2 When the adjustable output is used as CV output, first should 

rotate clockwise the CC adjustment (2) and (17) to maximum, then 

turn on power switch (13), adjust CV adjustment (4) and (14) till 

output voltage reach required voltage value. At this time, the CC 

state indicator (1) and (11) go out and the CV state indicator (3) and 

(12) light on. 

2.2.1.3 Used as CC output, after turning on power switch (13), first 

rotate clockwise the CV adjustment (4) and (14) to maximum, while 

rotate counterclockwise the CC adjustment (2) and (17) to minimum, 

then connect the required load, again adjust clockwise adjustment 

(2) and (17) till output current reach the required current value. At 

this time, the CV state indicator (3) and (12) go out and the CC state 

indicator (1) and (11) light on. 

2.2.1.4 Used as the CV output, in general the CC adjustment (2) and 

(17) should be set to maximum, but for this unit, the current-limiting 

protection point can also be set arbitrarily. 

Summary of Contents for ATH-2235

Page 1: ...User s Manual DC POWER SUPPLIES ATH 2235 ATH 2243 ATH 3231 ATH 3232 ATH 4012 Thank you for choosing AKTAKOM Power Supply www tmatlantic com...

Page 2: ...uipment to direct sunlight or extreme temperatures Do not subject the equipment to extreme humidity or dampness Replace a defective fuse only with a fuse of the original rating Never short circuit fus...

Page 3: ...lies have three ways output Of which two ways are adjustable and one way is fixed The two adjustable outputs can also be selected for constant voltage or constant current designed in high stability an...

Page 4: ...gulation Two adjustable output CV 1 x 10 4 3mV CC 2 x 10 3 3mA Fixed output 10mV 1 4 Load regulation Two adjustable outputs CV 1 x 10 4 2 mV I 3 A CV 1 x 10 4 5 mV I 3 A CC 2 x 10 3 3 mA I 3 A CC 2 x...

Page 5: ...ng slave output current by analog meter or LED LCD 6 Volt display indicating slave output voltage by analog meter or LED LCD 7 Control switch for selecting the two adjustable outputs independent serie...

Page 6: ...put 2 2 1 1 Set 7 and 9 switch to spring out position 2 2 1 2 When the adjustable output is used as CV output first should rotate clockwise the CC adjustment 2 and 17 to maximum then turn on power swi...

Page 7: ...onnected is series 2 2 2 3 When the two outputs are in series the voltage is controlled by master output but current adjustment of two outputs is still independent Therefore attention should be paid t...

Page 8: ...ter is 2 5 class To get more accurate measuring value you should calibrate by external circuit with precision measuring instrument 3 CAUTION 3 1 This unit has excellent protection function 5V output h...

Reviews: