Aktakom ATH-2235 User Manual Download Page 4

www.tmatlantic.com 

4

 

1. TECHNICAL DATA 

1.1 Input voltage: 110VAC ... 127VAC ±10% / 60Hz; 220VAC ... 

240VAC ±10% / 50Hz (SWITCHABLE) 

1.2 Output voltage and current of adjustable channels 

 

ATH-2235: 0…30V, 0…5A x 2 

 

ATH-2243: 0…40V, 0…3A x 2 

 

ATH-3231: 0…30V, 0…3A x 2 

 

ATH-3232: 0…30V, 0…5A x 2 

 

ATH-4012: 0…30V, 0…3A x 2 

1.3 Line regulation: 

Two adjustable output: 

 

CV = 1 x 10

-4

 + 3mV 

 

CC = 2 x 10

-3

 + 3mA 

Fixed output: 10mV 

1.4 Load regulation: 

Two adjustable outputs: 

 

CV = 1 x 10

-4

 + 2 mV (I 

3 A) 

 

CV = 1 x 10

-4

 + 5 mV (I >3 A) 

 

CC = 2 x 10

-3

 + 3 mA (I 

3 A) 

 

CC = 2 x 10

-3

 + 5 mA (I >3 A) 

Fixed output: 10mV 

1.5 Ripple and noise: 

Two adjustable output: 

 

CV = 0.5 mV rms (I 

3 A) 

 

CV = 1.0 mV rms (I >3 A) 

 

CC < 3mA rms 

Fixed output: 10 mV rms 

1.6 Protection: current-limit 

1.7 Display accuracy:  

Volt-indication: ±(0.2%Rdg+2 digits), ±2.5% Full Scale 

Amp-indication: ±(1.0%Rdg+2 digits), ±2.5% Full Scale 

 

Summary of Contents for ATH-2235

Page 1: ...User s Manual DC POWER SUPPLIES ATH 2235 ATH 2243 ATH 3231 ATH 3232 ATH 4012 Thank you for choosing AKTAKOM Power Supply www tmatlantic com...

Page 2: ...uipment to direct sunlight or extreme temperatures Do not subject the equipment to extreme humidity or dampness Replace a defective fuse only with a fuse of the original rating Never short circuit fus...

Page 3: ...lies have three ways output Of which two ways are adjustable and one way is fixed The two adjustable outputs can also be selected for constant voltage or constant current designed in high stability an...

Page 4: ...gulation Two adjustable output CV 1 x 10 4 3mV CC 2 x 10 3 3mA Fixed output 10mV 1 4 Load regulation Two adjustable outputs CV 1 x 10 4 2 mV I 3 A CV 1 x 10 4 5 mV I 3 A CC 2 x 10 3 3 mA I 3 A CC 2 x...

Page 5: ...ng slave output current by analog meter or LED LCD 6 Volt display indicating slave output voltage by analog meter or LED LCD 7 Control switch for selecting the two adjustable outputs independent serie...

Page 6: ...put 2 2 1 1 Set 7 and 9 switch to spring out position 2 2 1 2 When the adjustable output is used as CV output first should rotate clockwise the CC adjustment 2 and 17 to maximum then turn on power swi...

Page 7: ...onnected is series 2 2 2 3 When the two outputs are in series the voltage is controlled by master output but current adjustment of two outputs is still independent Therefore attention should be paid t...

Page 8: ...ter is 2 5 class To get more accurate measuring value you should calibrate by external circuit with precision measuring instrument 3 CAUTION 3 1 This unit has excellent protection function 5V output h...