6600 COUNTS DIGITAL MULTIMETER
USER'S MANUAL
25
Linear frequency
˄
6HZ~10KHZ
˅
Function
Range
Resolution
Accuracy
600mV 600mV
6.6V
2V
66V 10V
Frequency
(6Hz-66KHz)
660V 20V
±(0.05%+8)
Above accuracies can be guaranteed within 10%~100% of the full range.
4.2.4 Duty cycle
Range Resolution
Accuracy
1%
ī
99% 0.01%
±(2%+10)
4.2.5 Resistance
Range Resolution
Accuracy
660.0
:
0.1
:
6.600k
:
1
:
66.00k
:
10
:
660.0k
:
100
:
6.600M
:
1k
:
±(1.2%+2)
66.00M
:
10k
:
±(2%+5)
4.2.6 Diode Test
Range Resolution
Test
Condition
2 V
0.001V
Forward DC current approximately 1mA. Reversed
DC voltage approximately 2.8V.
: