Upon seeing that the SAM nozzle has successfully unpaired, pr
ess the “SEND BAM” button at the bottom of
the pairing screen on the UV1100. A pop-up window will appear, asking if you wish to continue. Click the
check mark button to proceed. The UV1100 will reboot.
11. CHARGING THE HOSE FROM THE
SAM™ SMART NOZZLE
A paired valve with the
SAM™ SMART NOZZLE can only be activated in pump
mode.
Do not activate a paired valve while hose is still packed in the hose bed, cross-lay
or speed-lay. Doing so will result in damage to the hose and surrounding structure
of the truck and may cause bodily injury due to rapid hose expansion and
movement.
When ready to activate a paired
SAM™ SMART NOZZLE and valve,
SIMULTANEOUSLY
press and hold
the two function buttons located on either side of the
SAM™ SMART NOZZLE module for a minimum time
of 2 seconds. Release after the 2 second period. The LED display on the
SAM™ SMART NOZZLE will
illuminate in a yellow wig-wag sequence as shown below indicating the signal to open the valve has
occurred. The wig-wag sequence will continue for approximately four (4) seconds and will then switch to
the tank level display discussed in section 11 of this manual. The valve at the truck will commence to open
and provide water to the
SAM™ SMART NOZZLE.