When ready to pair the
SAM™ SMART NOZZLE with a discharge valve,
SIMULTANEOUSLY
press and
hold the two function buttons located on either side of the SAM™ SMART NOZZLE module for a minimum
time of 2 seconds. Release after the 2 second period. The LED display on the SAM™ SMART NOZZLE will
illuminate in a blue wig-wag sequence as shown below indicating the signal to pair with a valve has
occurred.
Now, look at the SAM UV1100 display. It should show a passcode entry screen. Enter the appropriate
passcode to gain access to the SAM Nozzle and valve pairing menu.
Once entry is gained to the pairing menu, confirm that the Serial Number (SN) indicated on the menu
screen matches the SN on the left side of the
SAM™ SMART NOZZLE being paired. Then select the row
for the appropriate discharge
valve and click the “pair” button.