AKG MicroMic C417 III User Instructions Download Page 11

22

5 Troubleshooting

Problem

No sound:

Distortion:

Possible Cause

1. Power to mixer

and/or amplifier is
off.

2. Channel or master

fader on mixer, or
volume control on
amplifier is at zero.

3. Microphone is not

connected to mix -
er or amplifier.

4. Cable connectors

are seated loosely.

5. Cable is defective.

6. No supply voltage.

1. Gain control on

the mixer set too
high.

2. Mixer input sensi-

tivity too high.

Remedy

1. Switch power to

mixer or amplifier
on.

2. Set channel or

master fader on
mixer or volume
control on ampli-
fier to desired   
lev el.

3. Connect micro-

phone to mixer or
amplifier.

4. Check cable

connectors for se-
cure seat.

5. Check cable and re-

place if  damaged.

6. Switch phantom

power on.
Phantom power
supply: connect to
power outlet or in-
sert battery 
(batteries).
Check cable and re-
place if necessary.

1. Turn gain control

down CCW.

2. Connect a 10-dB

preattenuation
pad between
microphone cable
and input.

4

Summary of Contents for MicroMic C417 III

Page 1: ...fore using the equipment MODE D EMPLOI p 24 Veuillez lire cette notice avant d utiliser le syst me ISTRUZIONI PER L USO p 35 Prima di utilizzare l apparecchio leggere il manuale MODO DE EMPLEO p 46 An...

Page 2: ...rofessional miniature clip on microphone Omnidirectional condenser transducer for nat ural sound Extended frequency response for clear repro duction of speech vocals violin 1 Precaution Description 1...

Page 3: ...microphone and maximum mobility for the user The microphone is available in two different colors and will almost disappear when blended in with an actor s or singer s makeup An external windscreen su...

Page 4: ...LR micro phone input with phantom power 2 Switch the phantom power on Refer to the in struction manual of the unit to which you connected your microphone 3 If your mixer provides no phantom power Conn...

Page 5: ...s electric motors etc like an antenna This may introduce hum or similar noise when you use a cable that is longer than 16 feet 5 m The optional B 29 L battery supply allows you to connect the micropho...

Page 6: ...input Refer to section 2 2 2 above 1 Push the mini XLR connector 1 on the micro phone cable into the mini XLR socket 2 on the cable of the MPA III L 3 to the stop The connector will lock automaticall...

Page 7: ...optional AKG phantom power supply 4 N 62 E N 66 E B 18 B 15 and use an XLR cable 5 e g an optional MK 9 10 from AKG to connect the phantom power supply 4 to the desired balanced input Refer to the man...

Page 8: ...ance independently of the user s mo vements and thus ensure a constant output level Also a clip on microphone allows the user to move about freely and keeps their hands free 1 Insert the cable into on...

Page 9: ...ied H 40 1 clip se fig 5a or on the supplied H 41 tie pin see fig 5b 2 Fix the microphone on a suitable part of the stage decoration such as a flat backdrop cur tain etc Fix the microphone on the user...

Page 10: ...ist s cheek This method provides the following benefits Since the microphone is not mounted on the violin itself it will not affect the sound of the in strument There will be no risk of damaging the v...

Page 11: ...t too high 2 Mixer input sensi tivity too high Remedy 1 Switch power to mixer or amplifier on 2 Set channel or master fader on mixer or volume control on ampli fier to desired level 3 Connect micro ph...

Page 12: ...ry power supply MPA III L phantom adapter or AKG WMS bodypack transmitters Current consumption approx 2 2 mA Cable length Connector C 417III PP 3 m 10 ft 3 pin male XLR C 417III L PL 1 5 m 5 ft 3 pin...

Reviews: