18
5 Specifications
Polar pattern:
cardioid
Frequency range:
20 to 20,000 Hz ± 1.5 dB from published curve
Sensitivity:
9 mV/Pa = -41 dBV re 1 V/Pa
Electrical impedance:
< 200
Ω
Recommended load impedance: > 1000
Ω
Max. SPL for 0.5% THD:
112 Pa
Ⳏ
135 dB SPL with 0 dB preattenuation*)
355 Pa
Ⳏ
145 dB SPL with 10 dB preattenuation*)
1120 Pa
Ⳏ
155 dB SPL with 20 dB preattenuation*)
Equivalent noise level to DIN 45 412 (A-weighted): 18 dB-A
Dynamic range:
117 dB max. (A-weighted)*)
Preattenuation pad:
switchable to 0 dB, -10 dB, -20 dB
Highpass filter:
switchable to flat or 12 dB/octave at 75 Hz or 150 Hz
Powering:
9 to 52 V phantom power to DIN 45 596/IEC 268-15
Operating temperature:
-20°C to +60°C
Connector:
3-pin male XLR
Finish:
satin nickel plated
Size:
dia.: 19 mm (0.7 in.); length: 160 mm (6.3 in.)
Net/shipping weight:
125 g (4.4 oz.) / 760 g (1.7 lbs.)
*) Values measured with 48-V phantom power. Reduce by 2 dB for 24-V or 8 dB
for 12-V phantom power.
This product conforms to EN 50 082-1 (1997) provided it is connected to CE
marked equipment.
Frequency Response
Polar Diagram
0
°
150 Hz
75 Hz