27
6 Specifications
Type:
pre-polarized condenser microphone
Polar pattern: cardioid
Frequency range:
20 Hz to 20,000 Hz
Sensitivity at 1 kHz:
7 mV/Pa (-43 dBV re 1 V/Pa)
Impedance:
200
Ω
Recommended load impedance:
≥
2000
Ω
Max. SPL for 1%/3% THD:
126/130 dB SPL
Equivalent noise level:
31 dB (A) (to DIN 45412)
Power requirement:
C 419
III
PP: 9 to 52 V universal phantom power
C 419
III
L: B 29 L battery power supply,
MPA III L phantom adapter,
AKG WMS bodypack transmitters
Current consumption:
approx. 2 mA
Cable length/Connector:
C 419
III
PP: 3 m (10 ft.) / 3-pin male XLR
C 419
III
L: 1.5 m (5 ft.) / 3-pin mini XLR
Finish:
matte black
Size:
length: 180 mm (7.1 in.); dia.: 35 mm (1.4 in.)
Net/shipping weight:
C 419
III
PP: 141 g (5 oz.) / 462 g (16.3 oz.)
C 419
III
L: 77 g (2.7 oz.) / 398 g (14 oz.)
This product conforms to EN 50 082-1 provided it is connected to
equipment with a CE mark.
Frequency Response
Polar Diagram