Calculating Vent System Length 

To calculate the length of the system you 
need, add the equivalent feet (meters) for 
each vent piece used in the system. 

 

 

 

 

 

 

 

ELECTRICAL 

REQIUREMENTS  

 
 
Observe all governing codes and ordinances.  
Ensure that the electrical installation is 
adequate and in conformance with National 
Electrical Code, ANSI/NFPA 70 (latest  
edition), or CSA Standards C22.1-94, 
Canadian Electrical Code, Part 1 and C22.2 
No. 0-M91 (latest edition) and all local codes  
and ordinances. If codes permit and a 
separate ground wire is used, it is  
recommended that a qualified electrician 
determine that the ground path is adequate. 
A copy of the above code standards can be 
obtained from: 
National Fire Protection Association 
1 Batterymarch Park 
Quincy, MA 02169-7471 
CSA International 
8501 East Pleasant Valley Road 
Cleveland, OH 44131-5575 
 
 

 A 120 volt, 60 Hz., AC only, 15-amp, fused 

electrical circuit is required. 

 If the house has aluminum wiring, follow 

the procedure below: 
1.Connect a section of solid copper wire to 
the pigtail leads. 
2.Connect the aluminum wiring to the added 
section of copper wire using special 
connectors and/or tools designed and UL 
listed for joining copper to aluminum. 
Follow the electrical connector 
manufacturer's recommended  procedure. 
Aluminum/copper connection must conform 
with local codes and industry accepted 
wiring practices. 

 Wire sizes and connections must conform 

with the rating of the appliance as specified 
on the model/serial rating plate. The 
model/serial plate is located behind the filter 
on the rear wall of the range hood. 

 Wire sizes must conform to the 

requirements of the National Electrical Code, 
ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical 
Code, Part 1 and C22.2 No. 0-M91 (latest 
edition) and all local codes and ordinances.

 

 

 

Summary of Contents for 10A3(IS)-30

Page 1: ...e Care Guide For questions about features operation performance parts accessories or service call 1 626 453 0550 or visit our website at www akdytrading net IMPORTANT READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...18 WARRENTY SERVICES 20 RANGE HOOD SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and o...

Page 3: ...ive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces...

Page 4: ...access hole Screwdrivers Philips Straight blade Pliers Tape measure or ruler and pencil Electrical supplies for wiring Aluminum foils tape and or duct tape Hammer Jigsaw or saber saw Stud finder Parts...

Page 5: ...t is the installer s responsibility to comply with installation clearances specified on the model serial rating plate Canopy hood location should be away from strong draft areas such as windows doors...

Page 6: ...tertop height B Hood height from ceiling to bottom of the range hood filter surface D A C B C Hood height 24 61 0 cm min from electric cooking surface 27 68 6 cm min from gas cooking surface suggested...

Page 7: ...ld be installed to minimize conduction of outside temper atures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to wh...

Page 8: ...alley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper...

Page 9: ...nstall your hood 1 Disconnect power 2 Determine which venting method to use roof or non vented Range Hood Mounting Screws Installation 1 Determine and mark the centerline on the ceiling where the rang...

Page 10: ...nd ordinances There must be enough conduit and wires or home power supply cable from the fused disconnect or circuit breaker box to make the connection in the hood s electrical terminal box 3 For vent...

Page 11: ...11 6 Install the inner support frame to the holes on the range hood body with M4 12 screws 7 Remove all protective film from the duct cover 8 Attach inner Upper duct cover into outer Lower duct cover...

Page 12: ...12 8 Install Inner and outer duct covers on the range hood body 9 Install the outer support frame on to the ceiling with four 7 5 52 drywall anchors and M5 60 screws...

Page 13: ...sembly and attach it to the upper support frame Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury 2 Install M4 12 screws...

Page 14: ...wer RANGE HOOD USE The range hood is designed to remove smoke cooking vapors and odors from the cook top tea For best results start the hood before cooking and allow it to operate several minutes afte...

Page 15: ...er speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button The blower off button turns the blower off Adjusting the...

Page 16: ...ergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge then rinse with clean water and wipe dry Metal Grease Filter 1 Remove the filter by pulling the spring rel...

Page 17: ...Replacing the LED light Turn off the range hood and allow the LED to cool To avoid damage or decreasing the life of the new bulb do not touch bulb with bare fingers Replace bulb using tissue or wearin...

Page 18: ...verifying that the locking system in the connectors is well locked 4 If the connectors are not well connected Hold and press main connectors attached in the white plastic Push inwards the motor lamp...

Page 19: ...stic and that the locking system in the connectors is well locked 4 If the connectors are not well connected Hold and press main connectors attached in the white plastic Push inwards the motor lamp co...

Page 20: ...your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 10 Major appliances with original model serial numbers th...