On/Off.
Turns On/Off the zone by pressing the center of the button.
•
Set point temperature.
Adjusts the temperature scrolling the finger over the button.
•
Mode.
Choose the operating mode for the zone:
The system remains stopped independently of the other zones status.
The system works only with air systems in
ventilation
mode
when a zone is generating demand (Tª
setpoint
< Tª
room
).
The system works only with the system in
cooling
mode, when a zone is generating demand (Tª
setpoing
< Tª
room
).
The system works only with the system in
heating
mode, when a zone is generating demand (Tª
setpoint
> Tª
room
).
The system works with the
dry
mode in the air equipment, refreshing the environment to reduce the humidity, when
a zone is generating mode (Tª
setpoint
< Tª
room
).
•
Eco-Adapt.
Establishes the set point temperature range according:
The available temperature ranges are the ones allowed by the system.
The Master thermostat defines the range.
The range is from 24 to 30˚C in
cooling
mode and 15 to 22˚C in
heating
mode.
The range is from 25 to 30˚C in
cooling
mode and 15 to 21.5˚C in
heating
mode.
The range is from 26 to 30˚C in
cooling
mode and 15 to 21˚C in
heating
mode.
•
Fan speed
.
Select the fan speed:
Automatic speed.
Low speed.
Medium speed.
High speed.
•
Sleep Function.
Auto-off timer of the device. Press
to select how long it will take to turn off: 30, 60 or 90 minutes.
The icon remains highlighted in blue when the timer is activated. Delete the timer pressing again the icon and
selecting “STOP”.
Access from the options menu
to the “Anti-freezing”, “Control Stages” and “Grille Angle” parameters.
•
Anti-freezing.
Prevents the room temperature from lowering below 12 ºC, even if the zone is off (not available in Stop
Mode).
•
Control stages
.
Enables setting the cooling and heating stages in the selected zone or in all the zones of the system:
Air: Activates heating/cooling air in the selected zone.
Radiant: Activates heating/cooling radiant in the selected zone.
Combined: Activates both air and radiant heating/cooling in the selected zone and allows the user to select the heating
stage in the zone: Air, Radiant or Combined. The zone will start to run in Heating air stage and once the room
temperature reaches the set differential, the zone will activate the radiant stage.
Off: Deactivates the cooling/heating stage in the zone.
•
Grille Angle.
Allows defining the angle of the slats of the Airzone smart grilles in cooling or heating mode:
90º, angle by default
50º.
45º.
40º.
•
Adjust slats.
Allows defining the inclination type of the horizontal and vertical slats on the systems where this function
is available.
•
Lite.
Allows the adjustment of the base set point temperature of the Lite thermostat associated to the zone.