background image

43

ComPac 9/04-12

W

ARRANTY

7.1 L

IMITED

P

RODUCT

W

ARRANTY

If any part of your Marvair

®

 Air Conditioner, Heat Pump or Unit Ventilator fails because

of a manufacturing defect within fifteen months from the date of original shipment from
Marvair or within twelve months from the date of original start-up, whichever is the earlier
date, Marvair will furnish without charge, EXW Cordele, Georgia, the required replacement
part. Any transportation, related service labor, diagnosis calls, filter, driers, and refrigerant are
not included. The owner must provide proof of the date of the original start-up. The owner’s
registration card filed with Marvair, the contractor’s invoice, the certificate of occupancy or
similar document are examples of proof of the date of the original start-up.

In addition, if the hermetic compressor fails because of a manufacturing defect within

sixty months from the date of original shipment from Marvair

®

, Marvair will furnish without

charge, EXW Cordele, Georgia, the required replacement part.  Any related service labor,
diagnosis calls, filter, driers and refrigerant are not included. Marvair will pay for non-priority
shipping costs of the compressor during the first twelve months of the warranty period. After
the first twelve months of the warranty period, all costs of shipment and risk of loss during the
shipment of the compressor shall be the responsibility of the owner.

The owner of the product may ship the allegedly defective or malfunctioning product or

part to Marvair

®

, at such owner’s expense, and Marvair will diagnose the defect and, if the

defect is covered under this warranty, Marvair will honor its warranty and furnish the required
replacement part. All costs for shipment and risk of loss during shipment of the product to
Marvair and back to the owner shall be the responsibility and liability of the owner. Upon
written request by an owner, Marvair may arrange for remote diagnosis of the allegedly
defective or malfunctioning product or part but all costs for transportation, lodging and related
expenses with regard to such diagnostic services shall be the responsibility and liability of the
owner.

An owner requesting performance under this Warranty shall provide reasonable access to

the allegedly defective or malfunctioning product or part to Marvair

®

 and its authorized agents

and employees.

This warranty applies only to products purchased and retained for use within the U.S.A.,

Canada, and Mexico.  This warranty does not cover damage caused by improper installation,
misuse of equipment or negligent servicing.

THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PUR-

CHASER OF A MARVAIR

®

 HEAT PUMP OR AIR CONDITIONER AND IS IN LIEU

OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR USE, TO THE FULLEST EXTENT PERMITTED BY LAW.  IN NO EVENT SHALL
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR USE EX-
CEED THE TERMS OF THE APPLICABLE WARRANTY STATED ABOVE AND
MARVAIR SHALL HAVE NO OTHER OBLIGATION OR LIABILITY. IN NO EVENT
SHALL MARVAIR BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAM-
AGES OR MONETARY DAMAGES.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY

ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE-TO-STATE.  Some states
do not allow limitations or exclusions, so the above limitations and exclusions may not apply
to you.

                

Rev. 902

Supersedes 7/02

Summary of Contents for Marvair ComPac I AVP20

Page 1: ...44 Maintenance 47 Warranty 48 ComPac I and ComPac II Air Conditioner Product Manual Vertical Wall Mount Air Conditioners with Front Control Box Panel Models AVP20 24 30 36 42 48 60 72 P 81024 9 04 12...

Page 2: ...leshooting information in Chapter 4 If you are still unable to correct the problem contact the Factory at 1 800 841 7854 for additional assistance Please read the following Important Safety Precaution...

Page 3: ...ionRequirements 23 2 3 InstallationMaterials 24 2 4 PortingandDuctWork 26 2 5 FreshAirHoodInstallation 27 2 6 BracketInstallation 27 2 7 MountingtheUnit 27 2 8 ElectricalConnections 28 Start Up 3 1 Ch...

Page 4: ...actors 17 3d TypicalElectricalSchematic ComPac IIA CModels20 60 withElectronicControlBoard 18 3e TypicalElectricalSchematic ComPac IA CModel72 19 3f TypicalElectricalSchematic ComPac IIA CModel72 20 F...

Page 5: ...xternalpanels Allunitshaveinternaldisconnects optionalon460V Dependinguponstateandlocalcode requirements thisfeaturemayeliminatetheneedforanexternalbreakerordisconnect TheComPac IA Chasa0 15 manualout...

Page 6: ...42 1650 1585 1520 1450 1360 48 1900 1830 1760 1700 1620 60 1900 1830 1760 1700 1620 72 2100 1950 1800 1730 1660 20 24 30 36 42 48 60 72 MODEL LBS KG LBS KG LBS KG LBS KG LBS KG LBS KG COMPAC I A C 274...

Page 7: ...152 mm 24 0 610 mm 42 0 1067mm 60 0 1524mm 78 0 1981mm FRESH AIR HOOD 1 5 38 mm K O S 2 0 51 mm MOUNTING HOLES CTR TO CTR HEATER ACCESS COVER DISCONNECT ACCESS COVER FRONT VIEW R H SIDE VIEW BACK VIEW...

Page 8: ...8 ComPac 9 04 12 Figure 1c ComPac I A C ComPac II A C Dimensions Models AVP72 in inches mm SLOTS IN COMPAC II ONLY SLOTS IN COMPAC II ONLY...

Page 9: ...EconomizerOperation ComPac IIA COnly The economizer is a regulated damper system with controls The damper regulates the circulationofoutsideairintotheenclosure whentheoutdoorairconditionsaresuitable...

Page 10: ...uetoalossofacooling Y callorthefirstfault theunit re startwillbedelayed3minutesfromthetimethecontactorisde energized Note There isnodelayonbreakifthelockoutconditionisreset Delay on Make Oninitialpowe...

Page 11: ...00 PSIG AVP60 setting is 450 PSIG This protects the unit if airflow through the condenserisblockedoriftheoutdoorfanmotorfails Althoughthecontactsofthehighpressureswitchclosewhentherefrigerantpressuref...

Page 12: ...o approximately 300 PSIG the system must be manually reset once the lockout relay is activated Amanualresetisnecessarytopreventharmfulshort cycling Toresetswitch turn primarypoweroff thenbackonorturnt...

Page 13: ...fstainlesssteel Hot Gas Bypass ComPac I A C Only Usedinspecialtyapplications i e MagneticResonanceImaging MRI buildings toprevent magneticvoltagedisturbancecausedbycompressorcycling Twohotgasbypassopt...

Page 14: ...rsareavailablefromMarvair Aflagtypedetectsareduction ofairflowonthedischargesideofthefilter Whenareductioninairflowisdetected asignal issenttoasetofdrycontacts Formorereliable preciseindicationofadirt...

Page 15: ...ED MOTORS SEE MOTOR NAMEPLATE FOR WIRE COLOR 3 TRANSFORMER IS FACTORY WIRED FOR 230 VOLT OPERATION FOR LOWER VOLTAGES INTERCHANGE ORANGE AND RED LEADS INSULATE UNUSED LEADS 4 OPTIONAL CRANKCASE HEATER...

Page 16: ...16 ComPac 9 04 12 Figure 3b Typical Electrical Schematic ComPac I A C Models AVP20 60 with Electronic Control Board 5 6 TRANSFORMER...

Page 17: ...RMER IS FACTORY WIRED FOR 230 VOLT OPERATION FOR LOWER VOLTAGES INTERCHANGE ORANGE AND RED LEADS INSULATE UNUSED LEADS 4 OPTIONAL FIELD INSTALLED 270 OHM MINIMUM POSITION POTENTIOMETER 5 CRANKCASE HEA...

Page 18: ...18 ComPac 9 04 12 5 TRANSFORMER Figure 3d Typical Electrical Schematic ComPac II A C Models AVP20 60 with Electronic Control Board...

Page 19: ...0 HZ 1 PH POWER SUPPLY SEE DATA PLATE FOR AMPACITY FUSE SIZE DISCONNECT SHOWN 2 SPEED TAP FOR MULTISPEED MOTORS SEE MOTOR NAMEPLATE FOR WIRE COLOR 3 TRANSFORMER IS FACTORY WIRED FOR 230 VOLT OPERATION...

Page 20: ...OR AMPACITY FUSE SIZE DISCONNECT SHOWN 2 SPEED TAP FOR MULTISPEED MOTORS SEE MOTOR NAMEPLATE FOR WIRE COLOR 3 TRANSFORMER IS FACTORY WIRED FOR 230 VOLT OPERATION FOR LOWER VOLTAGES INTERCHANGE ORANGE...

Page 21: ...lledbytheH205Aenthalpycontroloroptionaldrybulbsensor H205AEconomizerChangeoverControl TheH205Aenthalpycontrollerrespondstothetotalheatcontentoftheoutdoorairtoprovide changeovertooutsideairforfreecooli...

Page 22: ...optional Thecontrollermodulatesthepositionoftheoutsideairdamper inresponsetoinputfromthe enthalpyandmixedairsensors Thecontrollerisdesignedtomaintainthesupplyairtemperature between50 to56 Fbymixingwar...

Page 23: ...3 Completeandmailthewarrantyregistrationcard Youmustconsiderallofthefollowingwhenchoosingtheinstallationsite 1 Noise Installtheunitsothattheleastamountofnoisewillbetransmittedto inhabited spaces 2 Co...

Page 24: ...Supply Thepowersupplymusthavetheappropriatevoltage phase andampacityforthemodel selected Voltagemustbemaintainedaboveminimumspecifiedvalueslistedbelow Refer tothedatastickerontheunitforampacityrequire...

Page 25: ...itorforAVP20 36 FieldInstalled Not recommendedforscrollcompressors AdditionalItemsNeeded Additionalhardwareandmiscellaneoussupplies notfurnishedbyMarvair areneededfor installation Forexample thelistbe...

Page 26: ...ns using duct work should be designed and installed in accordance with all applicable safety codes and standards Marvair strongly recommends referring to the currenteditionoftheNationalFireProtectionA...

Page 27: ...theshelterwalltomatchthisopening Allowsufficient clearance torun3 4 conduitthroughtheholeandtotheunit 2 Usinganappropriateandsafeliftingdevice settheunitonthebottomsupportbracket mountedonthewall Youm...

Page 28: ...city for the selected model 1 SizetheincomingpowersupplylinesaccordingtoCoderequirements Runthepower conductorsthroughtheknockoutsonthewallsideoftheunit ortothoseadjacentto theelectricalcontrolbox Use...

Page 29: ...chofthesetpointscanbequicklyandeasily changedinthefieldbytheinstaller ItcanbeusedwithMarvair sComPac Ior IIunique verticalpackagedwallmountairconditionersorMarvair senvironmentalcontrolunits See Comms...

Page 30: ...ftheLL357D2 RemoteSignalling Terminals5 7ontheComPac A Cterminalboardaredrycontacts whichcanbeusedforremotesignallingintheeventofa ccutoffonloworhighpressurelimit Continuousfanoperation Forcontinuousi...

Page 31: ...T WITH HUMIDITY CONTROLLER G R W Y 2 4 6 8 10 1 3 5 7 9 4 WIRE WALL THERMOSTAT Four 4 Conductor Color Coded 18 Gauge Thermostat Cable Field Supplied COMPAC II A C TERMINAL BLOCK NOTE Terminals 5 7 are...

Page 32: ...CONTACTS DRY NO C SMOKE HP LP LOCKOUT CONTACTS DRY NO NC C INPUT FROM TERMINAL BOARD 3 2 1 THERMISTOR CONTACTS 4 FACTORY INSTALLED 1 24 VAC connections only 2 For immediate shutdown of air conditione...

Page 33: ...mponentcooleraerosolmaybe sprayeddirectlyintotheenthalpysensortosimulatelowenthalpyconditions causingthe economizerdampertoopen Alternately when outdoor conditions are lower than the set point a sourc...

Page 34: ...Allowtheunitstorunfor2to3minutesthencheckthetemperaturedifferentialbetween thereturnairandthesupplyairwithdigitalthermometer Thetemperaturedifferential shouldbebetween12and20degreesdependingonambientt...

Page 35: ...gparts etc Begin deeper analysis only after making this initial inspection The troubleshooting information in this manual is basic The troubleshooting section contains problem solution charts for gene...

Page 36: ...r shorts 4 Note voltage range limitations specific to the compressor troubleshooting section 1 Loss or restriction of airflow 2 Restriction in refrigerant circuit 3 Refrigerant overcharge following fi...

Page 37: ...oltage condition must be corrected 2 Running Amperage Connect a clip on type ammeter to the common lead to the compressor Turn on the supply voltage and energize the unit The compressor will initially...

Page 38: ...ultconditionwillopenthecontactorandshutdowntheunit The contactorontheunitthathasthefaultconditionmustbeclosedbeforethesecondfault conditioncanberecognizedbythecontrolboard Thecontactorontheunitwiththe...

Page 39: ...008 21 50419 50419 50419 50419 50419 50419 50419 50419 22 50214 50214 50214 50214 50214 50214 50214 50214 23 01257 01257 01257 01257 01257 01257 01257 01257 24 70063 70063 70063 70063 70063 70063 7006...

Page 40: ...26 6 2 26 40 17 19 28 27 3 6 AVP20 36 Control Box with Mechanical Relays Contactors AVP20 24 Control Box with Electronic Control Board AVP30 36 Control Box with Electronic Control Board 31 30 33 42 4...

Page 41: ...rol Box with Electronic Control Board 38 12 9 42 8 33 13 11 4 31 30 34 1 36 20 7 5 32 18 14 16 OFF ON ON OFF 6 37 22 24 27 28 19 3 21 17 2 10 2 40 17 37 19 28 27 3 26 6 2 40 26 37 17 19 27 28 3 6 AVP2...

Page 42: ...d the cabinet air reliefs for dirt or obstructions Remove foreign objects such as leaves paper etc Ifthecondensercoilisdirty itmaybewashedoffwithacommercialsolventintended for this purpose TURN OFF PO...

Page 43: ...iscoveredunderthiswarranty Marvairwillhonoritswarrantyandfurnishtherequired replacement part All costs for shipment and risk of loss during shipment of the product to Marvair and back to the owner sha...

Page 44: ...thout charge EXW Cordele Georgia the required replacement Any transportation related service labor diagnosis calls filter driers and refrigerant are not included The owner of the product may ship the...

Reviews: