TROUBLESHOOTING
SM YUDE 2-A.1 GB
12-3
F4
F4
CTT failure
F5
-
RCT failure
P0
P0
IPM reset
P5
P5
Compressor phase current detection
problem
Phase current detection circuit for compressor has
problem.
P7
P7
HST failure
PCB is damaged
P8
P8
Heat sink overheating protection
1.
Insufficient grease on heatsink or poor
connection of heatsink to PCB
2.
Outdoor PCB problem.
P9
P9
AC contactor protection
Pc
Pc
Current sensor failure
PCB is damaged
Pd
Pd
Sensor connection protection
PE
PE
Temperature shift protection
PH
PH
DC over voltage protection
1.
AC power supply is higher than 265V
2.
Outdoor PCB circuit malfunction
PL
PL
DC under voltage protection
1.
AC power supply voltage is less than 150VAC
2.
Outdoor PCB circuit malfunction
H3
H3
Compressor over load protection
1.
Connection of compressor OLP is loosen (the
resistance for this terminal should be less than
1ohm)
2.
EEV connection problem or
damaged/Capillary problem
3.
Refrigerant leakage
H4
Overload protection
1.
Too high ambient temperature outdoor side
(cooling mode) or indoor side (Heating mode)
2.
Poor heat exchange (including blockage and
bad radiating environment )
H5
H5
IPM protection
1.
Abnormal power input voltage.
2.
Compressor wiring mistake.
3.
Liquid and gas valve are not open.
4.
EEV damaged or not proper working
5.
Poor heat exchange.
6.
Over charged system.
H6
H6
Outdoor DC Fan error
1.
Bad contact of DC motor feedback terminal.
2.
Bad contact of DC motor control end.
3.
Fan motor is blocked.
4.
Motor malfunction
5.
Malfunction of main board rev detecting circuit.
H7
H7
Desynchronizing of compressor
1.
Abnormal power input voltage.
2.
Compressor wiring mistake.
3.
Liquid and gas valve are not open.
4.
EEV damaged or not proper working
5.
Poor heat exchange.
6.
Over charged system.
Hc
Hc
PFC protection
1.
PFC module assembly problem.
2.
Poor heat exchange of Heatsink
3.
PFC reactor problem.
4.
Abnormal power voltage
5.
PFC circuit problem on PCB
Lc
Lc
Compressor startup failure
1.
Compressor wiring mistake
2.
Over charged system
3.
System not balanced before compressor
starting
4.
Compressor problem
Ld
Ld
Lack phase protection of compressor
1.
Phase current detection circuit for compressor
has problem.
2.
Comp wiring mistake
LF
LF
Compressor over speed
1. Compressor wiring mistake
2. The compressor wire go cross the relative
current sensor
3. IPM damage
U7
U7
RV is abnormal
1.
Supply voltage is lower than AC175V;
2.
Wiring terminal RV is loosened or broken;
3.
RV is damaged.
Summary of Contents for YUDE024
Page 21: ...PERFORMANCE DATA SM YUDE 2 A 1 GB 5 1 5 PERFORMANCE DATA...
Page 26: ...WIRING DIAGRAMS 8 2 SM YUDE 2 A 1 GB 8 2 AWAU YUDE036 H11...
Page 27: ...WIRING DIAGRAMS SM YUDE 2 A 1 GB 8 3 8 3 AWAU YUDE036 H13 TBD...
Page 28: ...WIRING DIAGRAMS 8 4 SM YUDE 2 A 1 GB 8 4 AWSI CADE024 030 036 N11 For model 30 42...
Page 30: ...WIRING DIAGRAMS 8 6 SM YUDE 2 A 1 GB 8 6 AWSI DBD024 030 036 N11...
Page 72: ...APPENDIX SM YUDE 2 A 1 GB 14 1 14 APPENDIX APPENDIX...