3. OUTDOOR UNIT INSTALLATION
7
GB-13
OUTDOOR UNIT
■
Where it is out of rain or direct sunlight.
■
Where it is well-ventilated and free from obstacles near the air inlet and air outlet.
■
Where does not increase the operating noise or vibration of the outdoor unit.
■
Where does not cause any drainage problem with discharged water.
■
Install the outdoor unit properly at a place that is durable enough to the weight of the outdoor unit.
■
Where provides appropriate clearances as outlined
■
Where the piping between the indoor and outdoor units is within the allowable limits.
■
In regions with snowfall and cold temperatures, avoid installing the outdoor unit in areas where it can
be covered by snow. If heavy snow is expected, a field supplied ice or stand and field supplied-installed
wind baffle should be installed to protect the unit from snow accumulation and blocked air intake.
■
When installing the outdoor unit in a place that is
constantly exposed to a strong wind, it is recommended
that a wind baffle be used.
3.1 INSTALLATION SITE CHOOSING
X
O
Strong wind
3.2 OUTDOOR UNIT MOUNTING DIMENSION
Outline dimension
800
554
333
340
W
H
D
A
B
012/
018
024
036
514
845
702
363
350
540
945
810
420
403
673
952
1333
415
404
048/060
634
Model
YDFA