11-25
CONTROL SYSTEM
SM YAZDCI 1-A.1 GB
11.8.3 Main
Menu
11.8.3.1 Menus
Default (refer to the note)
Technician Test (tt)
╚════════════╦══
Technician Test Cool (ttC)
╚══
Technician Test Cool (ttH)
Installation Test (it)
╚════════════╦══
Number of IDUs (nID)-
IDU_Numbers
║
╚═══════════════╦══
1
║
╠══
2
║
╠══
3
║
╚══
4
╠══
Begin test (bgn)
╠══
║
Test Result (pf)-
InstTestResult
(NUL/PAS/FAL/OAT/IDU/FLT)
║
Matrix Table Test Result (tbl)
InstTestMatrixResult
╚══
Problem Correction (Crt)
(Not to be implemented)
Diagnostics (dia)
╚════════════╦══
Outdoor Unit (o)
║
╚══════════════════
Outdoor Unit (oxx)
╠══
Indoor Unit A (a)
║
╚══════════════════
Indoor Unit A (axx)
╠══
Indoor Unit B (b)
║
╚══════════════════
Indoor Unit B (bxx)
╠══
Indoor Unit C (c)
║
╚══════════════════
Indoor Unit C (cxx)
╚══
Indoor Unit D (d)
╚══════════════════
Indoor Unit D (dxx)
Set Up (Stp)
╚═════════╦══
║
First IDU Wins (idu)
╠══
IDU A is master (a-p)
╠══
IDU B is master (b-p)
╠══
IDU C is master (c-p)
╠══
IDU D is master (d-p)
╚══
‘Forced mode’ input (Frc)
Status (Stt)
╚════════════╦══
IDU (IDU)
╠══
ODU (ODU)
╚══
Timer (Tr)
Notes:
The default presentation will be alternating repeatedly among the following for single and
1.
multi split units:
(‘id’ + the number of communicative IDUs number) shown for 2 sec.
o
The mode of the unit (Cl/Ht/Sb) shown for 2 sec.
o
Active fault (among ODU or IDUs number), each to be shown for 2 sec.
o
In diagnostics menu:
2.
xx means failure code.
o
Maximum 5 faults are presented for each unit (each IDUs/ODU). When no faults “--“
o
sign will be shown.
The active faults have higher priority for presentation than non active ones.
o
Non active faults are presented according to their chronological order, starting from the
o
latest one.
Whenever a new active fault occurs, it will be presented immediately.
o
Active faults are blinking, where non active ones do not.
o
The Status menu will be enabled to be presented and navigated, only by pressing
3.
escape together for more than 5 seconds under the main menu.