PROTECTION MODES
Your air conditioner includes several automatic protection modes, which enables you to use it
virtually at any time and in any season, regardless of the out door temperature. Some of the
protection modes are listed below:
Mode
Operation
conditons
Protection
from
Controlled
remedy
Cooling
Low outdoor
temperature
Freezing of the
evaporation unit
Stops compressor when
approaching freezing
conditions.
Resumes operation
automatically. Operating
indicator (B) blinks
continuously until the
temperature decreases.
High outdoor
temperature
Overheating of the
condnsing unit
Stops compressor when
approaching over
heating conditions.
Resumes operation
automatically.
Operating indicator (B)
blinks.
Heating
mode
Low outdoor
temperature
Freezing of the
condensing unit
High indoor
or outdoor
temperature
Overheating of the
evaporation unit.
12
and Dry mode
The air conditioner
reserves operation from
heating to cooling for
short periods to de-ice
the condensing unit.
Operating indicator (B)
blinks.
Stop compressor when
the evaporation unit
approaches overheating.
Resumes operation
automatically.
RCA INST MANUAL