2-5
PRODUCT DATA SHEET
SM YBD018 1-A.1 GB
2.5
PXD 50 DCI / YBD018
(1)
Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).
(2)
Airflow without external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)
Sound pressure level measured at 1-meter distance from unit.
Units
Btu/hr
kW
kW
W/W
V
Ph
Hz
A
W
W
A
A
H/M/L
RPM
H/M/L
m3/hr
Min
Pa
H/M/L
dB(A)
H/M/L
dB(A)
l/hr
mm
WxHxD
mm
kg
WxHxD
mm
kg
units
units
H
RPM
H
m3/hr
H
dB(A)
H
dB(A)
WxHxD
mm
kg
WxHxD
mm
kg
Units
units
kg(7.5m)
In.(mm)
In.(mm)
m.
m.
kW
Model Indoor Unit
PXD 50 DCI
Model Outdoor Unit
YBD 018
Installation Method of Pipe
Flared
Characteristics
Cooling
Heating
Capacity (4)
17060(5120-19790)
19110(4440-22180)
5.0(1.5-5.8)
5.6(1.3-6.5)
Power input (4)
1.51(0.4-2.0)
1.59(0.36-2.0)
EER (Cooling) or COP(Heating) (4)
3.31
3.52
Energy efficiency class
A
B
Power supply
220-240
1
50/60
Rated current
6.8
7.1
Power factor
0.97
0.97
Prated (IDU)
104
Prated (IDU+ODU)
2400
Starting current
10.5
Circuit breaker rating
20
INDOOR
Fan type & quantity
Centrifugal x 2
Fan speeds
1050/950/700
Air flow (1)
870/750/600
External static pressure
0
Sound power level (2)
65/60/53
Sound pressure level(3)
51/48/40
Moisture removal
2
Condenstate drain tube I.D
16
Dimensions
1200x630x190
Net Weight
30
Package dimensions
1300x726x273
Packaged weight
35
Units per pallet
7 units per pallet
Stacking height
7 levels
OUTDOOR
Refrigerant control
EEV
Compressor type,model
Rotary,Panasonic 5RS132ZAD21
Fan type & quantity
Propeller(direct) x 1
Fan speeds
910
Air flow
2160
Sound power level
63
Sound pressure level(3)
53
Dimensions
795x610x290
Net Weight
38
Package dimensions
945x655x395
Packaged weight
41
Units per pallet
9 units per pallet
Stacking height
3 levels
Refrigerant type
R410A
S
WDQGDUG
charg
H
1.26
Additional charge
No need
Connections
between units
Liquid line
1/4"(6.35)
Suction line
1/2"(12.7)
Max.tubing length
Max. 20
Max.height difference
Max. 10
Operation control type
Remote control
Heating elements (Option)
Others