background image

4

2. Air handling unit
2.1 Wall splits FLO INV

Being unobtrusive and comfortable to use, this appliance offers maximised ease
of installation allied to incomparable air quality in response to professional
installers’ and individual users’ expectations.

2.1.1 Compact, efficient

The extremely silent and compact indoors units provide effective air conditioning
for rooms of between 20 and 40 m².
Their sleek aresthetics blend discreetly into all types of interior décor.

2.1.2 Proven technology

The microprocessor controlled safety systems and operation guarantee
unequalled quality and comfort in use.
The alliance of leading edge technology with an ioniser ans an electristatic filter
for wall FLO provides for precisely controlled air conditioning comfort.

2.1.3 Total reliability

Equipped with rotary compressors with variable speed ,guaranteed for two years,
the outdoor units provide low energy consumption, low acoustic levels and high
corrosion resistance.

2.1.4 A.Q.S. 3 filtration levels for perfect air quality

In addition to the re-usaable filter, two further levels of air filtration are
incorporated in the INVERTER wall splits units:
• Active electrostatic filter neutralising odours ans capturing the finest particles

from the air.

• Photo catalytic filter breaking down the various pollutants contained in the air.

This filter automatically regeneraters itself on contact with light.

2.1.5 Ionisation

The air we breathe is electrically charged, with both positive and negative ions.
In closed and urban environments, the concentration of negative ions in the
atmosphere is reduced. The ionizer 

Airwell

 re-establishes the balance of negative

ions in our environment for optimal living comfort.
The ion generator installed on the unit generates a quantity of between 30.000
and 50.000 ions per cubic centimetre.

2.1.6

 Infrared remote control with batteries.

2.1.7

 Cooling connections possibilities : right, left or rear.

2.1.8

 Wall mounting plate.

PRESENTATION

Summary of Contents for K 12 INV

Page 1: ...V GINV GINV GINV A A A A A 1GB 1GB 1GB 1GB 1GB Cancels and replaces Range INVERTER Cooling capacity kW Heating capacity kW Flo 9 INV 2 56 1 3 3 3 05 1 03 4 Flo 12 INV 3 4 1 38 3 9 4 25 1 23 4 78 SX 9...

Page 2: ...APACITY 14 DIMENSIONS outdoor unit GC 20 indoor unit FLO 21 indoor unit SX 22 indoor unit K 23 INSTALLATION 24 CONNECTIONS 25 REFRIGERATION CONNECTIONS 26 REFRIGERANT CHARGE 27 ELECTRICAL SPECIFICATIO...

Page 3: ...The extended operating range Incorporating capacity modulation for energy savings of up to 35 PWM control Constant indoors temperature and regulation to within 0 5 C wall units Flo inv floor ceiling...

Page 4: ...rovide low energy consumption low acoustic levels and high corrosion resistance 2 1 4 A Q S 3 filtration levels for perfect air quality In addition to the re usaable filter two further levels of air f...

Page 5: ...sate tray with connections for vertical and horizontal installation Wall or ceiling support with fitting template providing rapid electrical and refrigerant connections before siting the unit Infrared...

Page 6: ...nd outdoors units are equipped with FLARE connectors thus enabling the use of FLARE type pipes refrigerating quality copper piping equipped with nuts at both ends 5 DOCUMENTATION Each unit is supplied...

Page 7: ...ight indoor unit Length x Depth x Height mm 810 x 190 x 285 820 x 190 x 630 571 x 571 x 287 Weight kg 10 10 5 19 5 21 26 26 Packed Length x Depth x Height mm 885 x 360 x 285 890 x 280 x 710 685 x 685...

Page 8: ...8 COOLING CAPACITY wall unit Flo 9 inv Cooling capacity W Outdoor DB temperature Outdoor DB temperature Powerconsumption W Indoor WB 19 Indoor WB 21 Indoor WB 23 Indoor WB 19 Indoor WB 21 Indoor WB 23...

Page 9: ...COOLING CAPACITY wall unit Flo 12 inv Cooling capacity W Outdoor DB temperature Powerconsumption W Outdoor DB temperature Indoor WB 19 Indoor WB 21 Indoor WB 23 Indoor WB 19 Indoor WB 21 Indoor WB 23...

Page 10: ...0 3000 3100 3200 3300 3400 3500 10 15 20 25 30 35 40 45 Cooling capacity W Outdoor DB temperature 500 600 700 800 900 1000 1100 1200 1300 1400 1500 10 15 20 25 30 35 40 45 Outdoor DB temperature Power...

Page 11: ...nsumption W 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 10 15 20 25 30 35 40 45 Outdoor DB temperature 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 10 15 20...

Page 12: ...2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 10 15 20 25 30 35 40 45 500 600 700 800 900 1000 1100 1200 1300 1400 1500 10 15 20 25 30 35 40 45 Outdoor DB temperature Outdoor...

Page 13: ...B temperature 2900 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 10 15 20 25 30 35 40 45 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 10 15 20 25 30 35 40 45 Outdoo...

Page 14: ...4 HEATING CAPACITY wall unit Flo 9 inv Heating capacity W Powerconsumption W Outdoor WB temperature Outdoor WB temperature Indoor DB 15 Indoor DB 20 Indoor DB 25 Indoor DB 15 Indoor DB 20 Indoor DB 25...

Page 15: ...5 HEATING CAPACITY wall unit Flo 12 inv Heating capacity W Powerconsumption W Outdoor WB temperature Outdoor WB temperature Indoor DB 15 Indoor DB 20 Indoor DB 25 Indoor DB 15 Indoor DB 20 Indoor DB 2...

Page 16: ...HEATING CAPACITY floor ceiling SX 9 inv Heating capacity W Powerconsumption W Outdoor WB temperature Outdoor WB temperature Indoor DB 15 Indoor DB 20 Indoor DB 25 Indoor DB 15 Indoor DB 20 Indoor DB...

Page 17: ...HEATING CAPACITY floor ceiling SX 12 inv Heating capacity W Powerconsumption W Outdoor WB temperature Outdoor WB temperature Indoor DB 15 Indoor DB 20 Indoor DB 25 Indoor DB 15 Indoor DB 20 Indoor DB...

Page 18: ...EATING CAPACITY colorado cassette K 9 inv Heating capacity W Powerconsumption W Outdoor WB temperature Outdoor WB temperature Indoor DB 15 Indoor DB 20 Indoor DB 25 Indoor DB 15 Indoor DB 20 Indoor DB...

Page 19: ...EATING CAPACITY colorado cassette K 12 inv Heating capacity W Powerconsumption W Outdoor WB temperature Outdoor WB temperature Indoor DB 15 Indoor DB 20 Indoor DB 25 Indoor DB 15 Indoor DB 20 Indoor D...

Page 20: ...20 100 mm 800 mm 150 mm 500 mm 400 mm Clearances INTAKE DISCHARGE side view front viex top view condensing unit GC 9 inv GC 12 inv DIMENSIONS Dimensions in mm...

Page 21: ...E DISCHARGE 100 mm 50 mm 50 mm 2300 mm Mounting template yo be used for location of indoor unit on the wall ceiling indoor unit outline Mounting plate outline Tubing wall opening for rear right routin...

Page 22: ...22 floor ceiling SX 9 inv SX 12 inv Clearances 900 mm 80 mm 50 mm 200 mm DIMENSIONS Dimensions in mm side view front view top view...

Page 23: ...ended ceiling Suspended ceiling Evaporator Fan Air intake grille Electrical connections Condensates drainage GAS valve LIQUID valve Fresh air intake Orifice for ducted air distribution into adjacent r...

Page 24: ...ance FLO Mounting plate supplied SX Support supplied K Fits into a suspended ceiling and it is attached by means of threaded rods on the mounting lugs indoor unit outdoor unit 1 The location must allo...

Page 25: ...wiring connections to be made between the indoors and outdoors units are fully explained in the Installation Instructions manual supplied with the equipment Cooling connections of the GC to the ST Ele...

Page 26: ...GC The indoor units are designed for refrigeration connection to the outdoors units by means of pipes with Flare connectors completely insulated refrigeration quality copper pipes with ends equipped...

Page 27: ...Charge to be added length of connections of 6 to 8 m length of connections of 8 m g m g m 5 9 Maximum height difference m 7 The R 407C charge is only contained in the outdoors unit The indoors unit co...

Page 28: ...out prior notice Models FLO inv SX inv K inv 9 12 9 12 9 12 Power supply 230 V 50 Hz Current input cooling Current input heating Linkings Cable section A A mm 4 5 4 x 1 5 5 4 7 1 4 x 1 5 4 1 4 8 4 x 1...

Page 29: ...ure and increasing operating time key for lowering set temperature and decreasing operating time Liquid crystal display I FEEL sensor Infrared signal emitter ROOM key ambient temperature display SET k...

Page 30: ...ting A C E Marketing A C E Marketing FRANCE FRANCE FRANCE FRANCE FRANCE 1 bis Avenue du 8 Mai 1945 Saint Quentin en Yvelines 78284 GUYANCOURT Cedex T l 33 1 39 44 78 00 Fax 33 1 39 44 11 55 www airwel...

Reviews: