2-3
PRODUCT DATA SHEET
SM FLODCI 2-A.4 GB
2.3 FLO
24
DCI
Model Indoor Unit
FLO 24
Model Outdoor Unit
GC 24
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity
(1)
Btu/hr
23188(5100~25575)
25916(5100~30000)
kW
6.8(1.5-7.5)
7.6(1.5~8.8)
Power input
(1)
kW
2.25(0.5-2.8)
2.35(0.45~3.0)
EER (Cooling) or COP(Heating)
(1)
W/W
3.01 3.23
Energy efficiency class
B
C
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Rated current
A
9.8
10.3
Starting current
A
15
Circuit breaker rating
A
20
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1300/1150/1000
1350/1200/1050
Air flow
(2)
H/M/L
m3/hr
950/800/650
1000/850/700
External static pressure
Min-Max
Pa
0
Sound power level
(3)
H/M/L
dB(A)
60/54/47
Sound pressure level
(4 )
H/M/L
dB(A)
47/41/34
Moisture removal
l/hr
2.5
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
1060x295x210
Weight
kg
15
Package dimensions
WxHxD
mm
1115x350x260
Packaged weight
kg
18
Units per pallet
units
16
Stacking height
units
8 levels
OUTDOOR
Refrigerant control
EEV
Compressor type,model
Two Rotary,Mitsubishi TNB220F
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H/L
RPM
850
Air flow
H/L
m3/hr
3600
Sound power level
H/L
dB(A)
66
Sound pressure level
(4)
H/L
dB(A)
56
Dimensions
WxHxD
mm
950x835x412
Weight
kg
65.5
Package dimensions
WxHxD
mm
1080x910x477
Packaged weight
kg
73
Units per pallet
Units
2
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant chargless distance
kg/m
2.4kg/30m
Additional charge per 1 meter
g/m
No Need
Connections between units
Liquid line
In.(mm)
3/8"(9.53)
Suction line
In.(mm)
5/8"(15.88)
Max.tubing length
m.
Max.30
Max.height difference
m.
Max.15
Operation control type
Remote control
Heating elements (Option)
kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
CONTENTS