SPECIFICATION
JMF Series 9 Version - 1
Model Indoor Unit
ELSI-JMF012-N11
Model Outdoor Unit
ELAU-JMF012-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Capacity
(1)
kW
3.370
3.516
EER /COP
(2)
W/W
3.21
3.61
Energy efficiency class
A
A
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
10
INDOOR
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1200/1050/800
1200/1050/850
Air flow
(3)
H/M/L
m3/hr
580/500/400
580/500/410
External static pressure
Min-Max
Pa
0
Sound power level
(4)
H/M/L
dB(A)
51
Sound pressure level
(5)
H/M/L
dB(A)
41/35/30
Moisture removal
l/hr
1.2
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
800 x275x188
Weight
kg
8
Package dimensions
LxWxH
mm
865x265x350
Packaged weight
kg
10
Stacking height
units
8
OUTDOO
R
Refrigerant control
Capillary
Compressor type, model
ROTARY
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
900
Air flow
H/L
m3/hr
1800
Sound power level
(4)
H/L
dB(A)
67
Sound pressure level
(5)
H/L
dB(A)
57
Dimensions
WxHxD
mm
780 x540x250
Weight
kg
28
Package dimensions
LxWxH
mm
910x335x585
Packaged weight
kg
30
Stacking height
Units
5
Refrigerant type
R410A
Refrigerant charge (standard connecting tubing length)
kg(5m)
0.8
Additional charge per 1 meter
gr / 1m
20
Connections between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
3/8"(9.53)
Max.tubing length
m.
20
Max.height difference
m.
8
Operation control type
Remote control
Heating elements
kW
Others