Model

AWSI-CFV030-N11

AWSI-CFV038-N11

Power supply

V-Ph-Hz

1/220~230/50/60

1/220~230/50/60

Cooling

Capacity 

kBtu/h

30.7

38.2

Capacity 

kW

9

11.2

Power input           

W

90

90

Current

A

0.45

0.45

Heating

Capacity        

kBtu/h

34.1

42.6

Capacity        

kW

10

12.5

Power input           

W

90

90

Current

A

0.45

0.45

Heating capacity at 

low temp.

kW

/

/

Operating current 

A

0.45

0.45

Indoor motor

Brand 

Broad ocean

Broad ocean

Model 

ZWK511B51008

ZWK511B51008

Type

DC

DC

Insulation class

E

E

IP class

IP40

IP40

Power input           

W

90

90

Power output

W

63

63

Capacitor       

μF

/

/

Speed (High/

Middle/Low) 

rpm

350-850

350-850

Indoor fan

Brand 
Type

Centrifugal

Centrifugal

Quantity

1

1

Indoor coil

Number of rows

2

2

Tube pitch (a) x row 

pitch (b)  

mm

21*13.3

21*13.3

Fin spacing 

mm

1.45

1.45

Fin type (code)
Tube outside dia. 

and type 

mm

Φ7

Φ7

Coil length x height 

x width  

mm

2132*210*26.6

2132*210*26.6

Number of circuits

10

10

/

/

Summary of Contents for AWSI-CFV007-N11

Page 1: ...Service Manual Round Way Cassette Type Indoor Unit...

Page 2: ...5 Wiring diagram 12 6 Electric characteristics 13 7 Air velocity and temperature distribution 14 8 Sound pressure level 15 9 Installation 16 10 Dip Switch Setting 34 11 Indoor Unit Control 37 12 Fail...

Page 3: ...N11 AWSI CFV048 N11 AWSI CFV060 N11 Unique round way air outlet no blind spot Innovative 4 independent air flow control 6 adjustable louver positions 1296 air flow combinations Move eye intelligent sy...

Page 4: ...oor motor Brand Broad ocean Broad ocean Broad ocean Model ZWK465B500011 ZWK465B500011 ZWK465B500011 Type DC DC DC Insulation class E E E IP class IP40 IP40 IP40 Power input W 30 30 30 Power output W 2...

Page 5: ...B 950KB PB 950KB PB 950KB Dimension mm 950 950 50 950 950 50 950 950 50 Packing mm 1013 1025 123 1013 1025 123 1013 1025 123 Net weight kg 6 5 6 5 6 5 Gross weight kg 9 9 9 Fresh air dimension mm Soun...

Page 6: ...r Brand Broad ocean Broad ocean Broad ocean Model ZWK465B500011 ZWK465B500011 ZWK465A000007 Type DC DC DC Insulation class E E E IP class IP40 IP40 IP40 Power input W 30 30 50 Power output W 22 22 36...

Page 7: ...B 950KB PB 950KB PB 950KB Dimension mm 950 950 50 950 950 50 950 950 50 Packing mm 1013 1025 123 1013 1025 123 1013 1025 123 Net weight kg 6 5 6 5 6 5 Gross weight kg 9 9 9 Fresh air dimension mm Soun...

Page 8: ...t A 0 45 0 45 Indoor motor Brand Broad ocean Broad ocean Model ZWK511B51008 ZWK511B51008 Type DC DC Insulation class E E IP class IP40 IP40 Power input W 90 90 Power output W 63 63 Capacitor F Speed H...

Page 9: ...B PB 950KB Dimension mm 950 950 50 950 950 50 Packing mm 1013 1025 123 1013 1025 123 Net weight kg 6 5 6 5 Gross weight kg 9 9 Fresh air dimension mm Sound pressure level H M L dB A 37 35 31 37 35 31...

Page 10: ...55 Indoor motor Brand Broad ocean Broad ocean Model ZWK511B51008 ZWK511B51008 Type DC DC Insulation class E E IP class IP40 IP40 Power input W 110 110 Power output W 78 78 Capacitor F Speed High Midd...

Page 11: ...B PB 950KB Dimension mm 950 950 50 950 950 50 Packing mm 1013 1025 123 1013 1025 123 Net weight kg 6 5 6 5 Gross weight kg 9 9 Fresh air dimension mm Sound pressure level H M L dB A 44 40 36 44 40 36...

Page 12: ...el 07 09 12 16 18 24 28 30 38 183 204 246 48 60 288 Decoration board 950mm Decoration board 950mm Drain pipe connection Ceiling hole 890mm Ceiling hole 890mm Gap between suspending rod 765mm Gap betwe...

Page 13: ...11 4 Piping diagram M Fan TC1 TC2 Indoor heat exchanger Gas pipe Flared joint Flared joint Liquid pipe Filter EEV Filter TA...

Page 14: ...01 CN102 N IN PUMP CN109 CN108 HEATER L N L N Wire Controller With Indoor Unit Error Indicate Indoor Unit Outdoor Unit LED1 2 LED3 4 LED5 LED Definition 1 2 5 4 3 1 2 4 3 1 2 4 3 1 2 1 2 1 2 1 2 1 2 3...

Page 15: ...0 39 1 24 36 0 31 50 50 AB282MRERA 1 50 60 220 198 242 0 39 1 24 36 0 31 50 50 AWSI CFV030 N11 1 50 60 220 198 242 0 71 2 28 63 0 57 90 90 AWSI CFV038 N11 1 50 60 220 198 242 0 71 2 28 63 0 57 90 90...

Page 16: ...14 7 Air velocity distribution Air flow m3 h CFV007 018 CFV024 CFV030 038 CFV048 060 1 Strong speed 2 High speed 3 Medium speed 4 Low speed 5 Quiet...

Page 17: ...125 125 125 250 250 250 500 500 500 1000 1000 1000 2000 2000 2000 4000 4000 4000 8000 8000 8000 10 10 10 20 20 20 20 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60 70 70 70 70 Octave band center freq...

Page 18: ...ape is not allowed The wirings should be reliably connected to avoid the cover and the plate of the electrical cabinet lipping the wiring Improper installation might cause such accidents as heating or...

Page 19: ...can be used Please do not press the liquid crystal zone of controller to prevent damage Cleaning the unit with water may cause electric shock Do not put flammable spray close to the air conditioner Do...

Page 20: ...gently lift it 45 degree as shown in Fig 2 and then remove the air inlet grid 2 Dismantle the gauze press the outer frame of the air inlet grid by the thumb and draw the base angle of gauze by the fo...

Page 21: ...ntled to clean as below Cleaning Wind Deflector Do not wipe the wind deflector with water forcibly to avoid the floss falling off Maintenance before and after Operating Season Before Operating Season...

Page 22: ...refrigerating operation while other indoor units are in heating operation When the operator set it to the refrigerating or heating mode and the operation is opposite to the setting it displays the awa...

Page 23: ...let port of the machine and the floor is not more than 2 7m 4 Where air inlet outlet of the indoor units are not blocked 5 Where it is hard enough to bear the weight of the unit 6 Where there is no te...

Page 24: ...efrigerator and drainage and wiring connection line for remote control and connection line of indoor units and outdoor units connected to indoor units before suspending the indoor unit so as to make t...

Page 25: ...the installation of the ceiling 3 Adjust the unit to the proper installation location 4 Check if the unit is in the horizontal level The indoor unit is equipped with a built in drainage pump and a fl...

Page 26: ...here is a clearance air leakage or water leakage is likely to occur Caution Improper tightening of bolts would lead to the faults shown in the following figure 1 2 3 4 Jack catch Jack catch Jack catch...

Page 27: ...r removing For reference The method for removing angle trim panels when the installation of trim panel is complete a Insert a straight screwdriver in the notch Gently turn the screwdriver downward and...

Page 28: ...lating materials as shown in the drawing Hose Hose clamp Attached heat insulating material Heat insulating material Horniness pvc pipe Confirming Drainage The drainage should be confirmed during the t...

Page 29: ...024 060 N11 Tubing size mm Gas pipe 9 52 12 7 15 88 Liquid pipe 6 35 6 35 9 52 Tubing material Phosphor deoxy bronze seamless pipe TP2 for air conditioner Outer Diameter of Tubing mm Mounting Torque N...

Page 30: ...connection methods for the circular terminals are shown as follows loosen the screw before putting the line terminal into the terminal tier tighten the screw and confirm it has been clamped by pulling...

Page 31: ...id melting the insulating layer of cables which may cause accidents After connected to the terminal tier the tubing should be curved into be a U type elbow and fastened with the pressing clip Controll...

Page 32: ...nnects with the ABC terminal of indoor unit Outdoor 1 Indoor 1 Indoor 2 Indoor 3 Indoor 4 Indoor 5 Outdoor 2 Outdoor 3 C Indoor Wired controller B Two wired controllers control one indoor unit Either...

Page 33: ...01_1 SW01_2 SW01_3 SW01_4 Wired control address 1 2 3 4 Wired control address OFF OFF OFF OFF Master unit in group control OFF OFF OFF ON Slave unit 1 in group control OFF OFF ON OFF Slave unit 2 in g...

Page 34: ...of signal line exceeds 1000m Items Total current of indoor units A Cross section mm2 Length m Rated current of overflow breaker A Rated current of residual circuit breaker A ground fault Interruptor m...

Page 35: ...oling heating mode Repress ON OFF button to quit the compulsive running and stop the operation of the air conditioner check if the mains voltage is matching check if there is air leakage at the piping...

Page 36: ...34 10 Dip Switch Setting 10 1 0151800227 PCB dip switch setting Used for Round way smart air flow cassette type indoor units SW01 SW03 CN29 CN27 LED3 LED4 LED5 LED1 LED2 LED7...

Page 37: ...016 N11 OFF ON ON OFF 2 0HP AWSI CFV018 N11 OFF ON ON ON 2 5HP AWSI CFV024 N11 ON OFF OFF OFF 3 0HP ON OFF OFF ON 3 2HP AWSI CFV030 N11 ON OFF ON OFF 4 0HP AWSI CFV038 N11 ON OFF ON ON 5 0HP AWSI CFV0...

Page 38: ...29 for 2 seconds at the same time enter shorten time running the running time Before power on short CN27 after power on the unit enter self inspection Before power on short CN 27 and CN29 enter the pr...

Page 39: ...mote controller firstly judge the outdoor current mode If it is normal mode the indoor will run as the request of wired controller if it is abnormal mode the command can not be executed and indoor kee...

Page 40: ...enter compulsory cooling heating In compulsory cooling display LL and COOL will flash In compulsory heating display HH and HEAT will flash fan speed is AUTO At this time only ON OFF TEMP are valid 11...

Page 41: ...e 26 C lock function is unavailable Setting method for AWSI CCV060 N11 by remote controller Power on the unit press the LIGHT button 12 times buzzer echoes 4 times the unit panel will display A then p...

Page 42: ...04 Dual heat source sensor TW failure 05 5 05 Indoor EEPROM failure 06 6 06 Communication between indoor and outdoor failure 07 7 07 Communication between indoor and wired controller failure 08 8 08 I...

Page 43: ...No No No No Reconnect If float switch works Modify the wiring and the circuit If CN4 is with AC220V voltage If water pump works Check indoor PCB and replace it if necessary Check water pump If water p...

Page 44: ...chip is damaged Check if PCB is faulty if yes replace it Replace it Reconnect If wiring between P and Q is normal If communication wire is connected with multi outdoors Modify the wiring Modify the co...

Page 45: ...Yes If the port of CN15 on indoor PCB is normal If the port of CN19 on outdoor connecting board is normal If outdoor power source is normal If power supply is failure If there is noise Modify the com...

Page 46: ...n If there is indoor unit set as No 0 Set one indoor unit as No 0 Set only one indoor unit as No 0 Set one indoor unit as No 0 If there is indoor unit set as No 0 If there are multi indoors set as No...

Page 47: ...45 12 No 50Hz zero passage signal Check if the transformer is well Replace transformer Reconnect Replace PCB Yes Yes No No Check if the wiring of the wired controller connect well...

Page 48: ...46 14 DC motor failure Check if the wiring of motor is fixed well If the motor is fault Reconnect Replace motor Replace the PCB No No Yes Yes...

Page 49: ...Replace the driver module If the pressure difference between high and low pressure less than 0 4Mpa before the failure occurs replace the inverter compressor Adjusting the running range Adjust it cor...

Page 50: ...9 2 8 4 2 7 4 2 2 6 22 5 3 5 2 7 3 6 2 7 3 7 2 7 3 8 2 7 3 9 2 8 4 2 7 4 1 2 6 25 3 5 2 7 3 5 2 7 3 7 2 6 3 7 2 7 3 8 2 8 4 2 7 4 1 2 6 27 5 3 4 2 6 3 5 2 7 3 6 2 6 3 7 2 7 3 8 2 7 3 9 2 7 4 1 2 6 30...

Page 51: ...8 8 6 9 6 2 9 4 6 9 7 5 9 43 8 5 9 8 2 6 8 5 5 9 8 7 6 8 9 6 2 9 3 6 9 6 5 8 112 20 11 8 11 2 8 2 11 6 8 11 9 8 1 12 1 8 3 12 5 8 1 13 7 9 22 5 10 9 8 11 1 8 2 11 5 8 11 8 8 12 8 3 12 4 8 1 12 9 7 8...

Page 52: ...0 4 0 3 1 2 8 2 5 12 5 12 4 9 8 8 6 6 0 4 0 4 0 3 1 2 8 6 0 12 5 12 5 9 8 8 6 6 5 4 2 4 0 3 1 2 8 6 5 13 2 12 5 9 8 8 6 10 0 4 5 4 0 3 1 2 8 10 0 14 1 12 5 9 8 8 6 12 5 4 8 4 0 3 1 2 8 12 5 15 0 12 5...

Page 53: ......

Page 54: ...Round Way Cassette Type Indoor Unit Service Manual Airwell Residential SAS 3 avenue du centre B t A Les Quadrants 78280 Guyancourt France...

Reviews: