HMF R22 Series 32 Version
- 1
When the compressor is on, the indoor fan can be set to high/med/low/auto. And the anti-cold
wind function has the priority. If the compressor stops caused by the room temperature rising and
T2
≥
TE1-6, the indoor fan will be forced to run at breeze for 127 seconds, if T2<TE1-6, the indoor
fan will stop immediately.
For
AWSI-HMF009-H61, AWSI-HMF012-H61:
TE2
TE3
TE2-4
TE1
T2
TE3-4
Setting
Low
Breeze
TE1-4
High
Low
Off(Breeze)
Medium
Medium
When the compressor is on, the indoor fan can be set to high/med/low/auto. And the anti-cold
wind function has the priority. If the compressor stops caused by the room temperature rising and
T2
≥
TE1-4, the indoor fan will be forced to run at breeze for 127 seconds, if T2<TE1-4, the indoor
fan will stop immediately.
For other models:
TE2
T2
TE1
Setting
Off
TE3
TE4
Low
When evaporator coil temp.T2 is getting higher,