2-1
PRODUCT DATA SHEET
SM HDDHED 1-A.1 GB
2.1
HDD009 / HED009 // YDD 009
Model Indoor Unit
HDD/HED009
Model Outdoor Unit
YDD 009
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity
(4)
kW
0.45-3.23))2.65
0.45-4.1))3.52
Power input
(4)
kW
0.2-1.35))0.8
0.2-1.45))0.95
EER (Cooling) or COP(Heating)
(4)
W/W
3.30
3.70
Energy efficiency class
A
A
Power supply
V
220-240
Ph
1
Hz
50
Rated current
A
6.3
6.8
Power factor
0.97
0.97
Prated (IDU+ODU)
W
1550
Circuit breaker rating
A
16A
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
Cooling
SH/H/M/L
RPM
1300/1100/900/700
Heating
SH/H/M/L
RPM
1300/1140/980/820
Air flow
(1)
SH/H/M/L
m3/hr
630/520/370/280
External static pressure
Min
Pa
0
Sound power level
(2)
SH/H/M/L
dB(A)
51/46/40/34
Sound pressure level
(3)
SH/H/M/L
dB(A)
41/36/30/24
Moisture removal
l/hr
0.8
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
770x283x201
Net Weight
kg
8
Package dimensions
WxHxD
mm
844x342x261
Packaged weight
kg
11
OUTDOOR
Refrigerant control
Capillary
Compressor type, model
Rotary,Daikin 1YC23AEXD
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H
RPM
930
Air flow
H
m3/hr
1600
Sound power level
H
dB(A)
57
Sound pressure level
(3)
H
dB(A)
47
Dimensions
WxHxD
mm
658x550x275
Net Weight
kg
28
Package dimensions
WxHxD
mm
771x592x348
Packaged weight
kg
32
Refrigerant type
R410A
Standard charge
kg(5m)
0.74
Additional charge
15g/m(5m<L<15m)
Connections
between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
3/8"(9.53)
Max.tubing length
m.
Max. 15
Max.height difference
m.
Max. 5
Operation control type
Remote control
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2.
PRODUCT DATA SHEET