2-2
PRODUCT DATA SHEET
SM HDDHED 1-A.1 GB
2.2
HDD012 / HED012 // YDD 012
Model Indoor Unit
HDD/HED012
Model Outdoor Unit
YDD 012
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity
(4)
kW
3.53(0.6-3.96)
4.1(0.6-5.13)
Power input
(4)
kW
1.1(0.22-1.45)
1.14(0.22-1.55)
EER (Cooling) or COP(Heating)
(4)
W/W
3.21 3.61
Energy efficiency class
A
A
Power supply
V
220-240
Ph
1
Hz
50
Rated current
A
6.5
7.8
Power factor
0.97
0.97
Prated (IDU+ODU)
W
1650
Starting current
A
Circuit breaker rating
A
16
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
Cooling
SH/H/M/L
RPM
1350/1150/950/750
Heating
SH/H/M/L
RPM
1350/1190/1020/850
Air flow
(1)
SH/H/M/L
m3/hr
680/560/410/330
External static pressure
Min
Pa
0
Sound power level
(2)
SH/H/M/L
dB(A)
52/47/41/35
Sound pressure level
(3)
SH/H/M/L
dB(A)
42/37/31/25
Moisture removal
l/hr
1.5
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
770x283x201
Net Weight
kg
9
Package dimensions
WxHxD
mm
844x342x261
Packaged weight
kg
12
OUTDOOR
Refrigerant control
Capillary
Compressor type, model
Rotary,Daikin 1YC23AEXD
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H
RPM
930
Air flow
H
m3/hr
1600
Sound power level
H
dB(A)
58
Sound pressure level
(3)
H
dB(A)
48
Dimensions
WxHxD
mm
658x550x275
Net Weight
kg
30
Package dimensions
WxHxD
mm
771x592x348
Packaged weight
kg
34
Refrigerant type
R410A
Standard charge
kg(5m)
1
Additional charge
15g/m(5m<L<15m)
Connections
between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
3/8"(9.53)
Max.tubing length
m.
Max. 15
Max.height difference
m.
Max. 5
Operation control type
Remote control
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.