5-1
4
S
E
V
R
U
C
E
R
U
S
S
E
R
P
&
A
T
A
D
E
C
N
A
M
R
O
F
R
E
P
SM
HJD
DCI 1-A.1 GB
5.8.3
Model: HJD0 24 / YBDE024 Cooling
— Test Mode
.
Discharge Pressure vs. Outdoor Temperature
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
10
15
20
25
30
35
40
45
Outdoor DB Temperature
Discharge Pressure [kPa]
22/15
24/17
27/19
29/21
32/23
Indoor
DB/WB
Suction Pressure vs. Outdoor Temperature
600
700
800
900
1000
10
15
20
25
30
35
40
45
Outdoor DB Temperature
Suction Pressure [kPa]
22/15
24/17
27/19
29/21
32/23
Indoor
DB/WB