OPERATING INSTRUCTIONS
28
Advanced settings
To change advanced settings touch
at start screen.
Enter code “1
-3-
5”
, continue with
and choose desired submenu.
Submenu in Level 135
meaning
Factory
setting
Choices
Production
speed
66 ft./min
- 8 m/min (26ft/min)
- 12 m/min (66ft/min)
- 20 m/min (39ft/min)
With Jumbo roll holder:
- 12JR / 20JR
Start/Stop with
connected ext.
tool
Deactivated
- External sensor
- Foot pedal
- Large roll coiler
- Deactivated
Delay time
sensor reaction
0
Off/0 - 99 sec
Foil detection
sensor
Roll holder
- Roll holder
- Jumbo roll holder
- Airpipe
- All deactivated
Resting time
until machine
starts cooling
20 min
Off/0
–
99 min
Imperial or
metric units
°F & Feet
- °C
- °F
- Meter
- Feet
Time of day
24 h
- am/pm
- 24 h
hh : mm
Date
mmdd
- mmdd
- ddmm
Internal section
-
-
-
Delay “Start”
via
display
0
0
–
99 sec
Blower starts
before/after
film transport
0.0
0 : Motor & blower
same time
–
: Blower before motor
(0,1 - 1,0 sec)
+ : Blower after motor
(0.1 - 1.5 sec)
Running speed
External control
Delay time ext. sens.
Foil detection sensor
Standby time
Units
Time
Date
Communication
Start delay time
Blowing time
Summary of Contents for AirWave2