Before using the monitor, check to make sure the monitor is not damaged in any way.
Open any packaging with care and do not use any sharp implements that might damage the
monitor. In case of doubt, please contact Airtocheck.
The monitor is shipped including:
-
Manual
-
Power cable
-
3-metre pressure hose(s)
-
SD card (only ever use the supplied SD card)
-
Printer roll
-
SIM card (only for the web-based version)
!
The Airtocheck monitor must only ever be used outside the contaminated area.
Installation
-
Determine the correct location (near a wall socket and near the area to be measured).
-
If applicable, check the web-based settings.
-
We recommend that you do not place the monitor near windows, fans/heaters or in similar circumstances
that may cause pressure variations.
-
Connect the pressure hose to measuring point p1- (if using 1 containment).
Please note!
If you press the hose in too far, it may get stuck. When removing the hose, continually press
the upper ring, but bear in mind that if you press to hard, the hose and/or monitor may get
damaged. Only ever use the originally supplied hose(s). When measuring a second
containment, connect the second pressure hose to p2- (channel p2- is optional).
Please note!
Switch on the second channel by activating Sensor 2 (see Menu; RESULTS > Sensor) and check
whether the measurement data from
both
channels is being shown on the display.
-
Connect the power cable to the monitor (21) (check the cable for any breakage and/or damage).
-
Connect the monitor to the mains voltage.
-
Install a thermal registration roll in the printer (8).
Please note!
Install the printer roll properly so that it will turn in the right direction
.
-
If desired, install an SD card (20) – only ever use the card supplied with your monitor.
-
Press the on/off switch (4). The startup process will take around 60 seconds.
-
Check access (for the Internet version, the strength of the RSSI signal must be at least >10).
-
Check whether the measurement data is being received by your Airtocheck account.
-
The system is now ready to be used.
Connecting the hose (P1/P2)
Disconnecting the hose