background image

 

4.  Press  the 

 button  to  choose  a  desirable  humidity  setting.  The  indicator 

will  show  the  setting  you  have  selected.  In  order  to  keep  the  room  at  the 
selected level of humidity/comfort the unit will cycle ON and OFF.  

NOTE: 

 

L (low) the unit will keep the humidity level around the 30% RH 

 

Between L and M unit will keep the humidity level around the 40% 

RH 

 

M (medium) the unit will keep the humidity level around the 50% RH 

 

Between M and H unit will keep the humidity level around the 60% 

RH 

 

H (high) the unit will keep the humidity level around the 70% RH 

 

C (continuously) the unit will work continuously 

5. Use the Timer button 

 to set the unit to automatically switch off in 2, 4 or 

8 hours. While the unit is running, you can set the timer to switch the unit off.  
6.  This  product  is  designed  to  allow  the  use  of  an    external  humidistat  device 
connected with the power supply cord. If using an external humidistat, press the 

 button so that the humidity level can be solely set by the external device. 

The  timer  also  doesn’t  work  in  this  mode,  Only  the  Fan  speed  can  be  altered 
between High, medium and Low. 
7. Top cover is equipped with a child lock. Please use a small coin or flat head 
screwdriver to unlock it. When the cover is opened for servicing or removing the 
water  wheel,    the  power  will  be  cut-off  automatically  to  avoid  any  electrical 
shock/injury. 
8.  When  the  water  level  drops  to  the  Min  level,  there  will  be  a  10sec  audible 
alarm and the red light will illuminate and keep flashing. You can only reset it by 
re-filling water into the tank. 
9. This humidifier has a memory function .When the unit is routinely turned off  
without  any  power  interruption,  the  previous  Fan  &  Humidity  settings  will 
become the default settings when the unit is switched on the next time.

 

This is 

often referred to as auto restart after power cut. 
10. The unit has 6 casters of which two are lockable. These two casters are at 
the left and right of rear side of the unit. We strongly recommend when the unit 
is in operation these two casters are locked by pushing down the lock lever.   

IMPORTANT: 

 

once  the  room  humidity  is  higher  than  the  set  parameter,  the  unit 
will not turn on 

 

Move the unit gently and very carefully when it is filled with water in 
order  to  avoid  water  splashing  onto  the  floor  or  internal  electrical 
parts. 

 

When  restarting  the  unit  or  opening  and  re-placing  the  top  cover, 
TANK FULL and TANK EMPTY sensors will re-detect the water level, 
and give the signals accordingly. 

Summary of Contents for PCMH45-DW

Page 1: ...t with an optimum of energy saving for a long period of time Please read this instruction manual before operating and keep safe for future reference Get to know your unit Read this guide carefully and...

Page 2: ...given supervision or instruction concerning use of the appliance by a person responsible for their safety People who have not read this manual or are not use to this kind of product should not be all...

Page 3: ...ed BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal whic...

Page 4: ...ot to damage it Locating your humidifier For best results we recommend you locate your unit in the middle of a room Do not place the humidifier near furniture paintings or any other object which could...

Page 5: ...earings at both ends correctly to ensure the correct movement of the water wheel FILLING THE WATER 1 Lift up the water inlet cover Fill the water into the tank through the water inlet tube Figure 1 On...

Page 6: ...y Please connect the hose tightly onto the connector at the back of the tank using a 25 4mm female screw nut Connect the other end of the hose to your water tap NOTE The tank is equipped with an overf...

Page 7: ...Weight 12 4Kg Gross Weight 17Kg WIRING DIAGRAM OPERATION FEATURES 1 Plug the power cord into a properly grounded 220 240Volt AC outlet The power indicator will illuminate 2 To turn the unit on press...

Page 8: ...lock Please use a small coin or flat head screwdriver to unlock it When the cover is opened for servicing or removing the water wheel the power will be cut off automatically to avoid any electrical sh...

Page 9: ...ar depending on the amount of use water hardness local air pollution To replace the pads open the humidifier top cap figure 3 Take out the air flow direction part figure 4 Remove the wheel carefully f...

Page 10: ...clean this by using a vacuum cleaner and rinse in warm water Before replacing ensure that the dust filter is fully dry Replace the dust filter and replace the filter protection guard and fix with the...

Page 11: ...ipt as proof of purchase To ensure your product is covered by warranty the complete faulty product together with your purchase receipt should be returned to your retailer This product has been manufac...

Reviews: