6
Power supply
Depending on the model, you have to access different sites to make your connection:
K7 600 A OH+FC (with standard control) -> On one of the outer sides there is the power board, where the
power must be connected.
K7 600 A OH+FC CL (with advanced Clever control) -> On one of the outer sides there is a black box where
the power supply must be connected.
K7 600 A OH+FC SS (IP55 standard control) -> There is a waterproof box above the purifier where the power
must be entered and connected to the internal terminal block by means of a cable gland.
PCB and control
Depending on the model, you have to access different sites to make your connection. All models include an
RJ telephone cable to communicate with the control.
K7 600 A OH+FC (with standard control) -> using the 7-meter RJ45 cable, connect the power board (located
on one of the outer sides of the purifier) and the control. In this case, it is not necessary to open the intake
grille.
K7 600 A OH+FC CL (with advanced Clever control) -> using the 7-meter RJ11 cable, connect the Clever
regulation board (located inside the equipment) and the TFT control of the Clever. In this case, it is necessary
to open the intake grille (see section
“repairs and replacements”). The RJ11 cable must be routed to the
outside through a hole in the top of the housing.
K7 600 A OH+FC SS (IP55 standard control) -> using the 7-meter RJ45 cable, connect the power board
(located in the waterproof box above the purifier) and the control (located inside an IP65 waterproof box). To
enter the cable in each box, you must use the cable glands supplied with the purifier.
The communication between the controller and the board is digital and low voltage.
There are optional accessories and controllers designed to meet the needs of each client (Clever, brackets,
etc.).
The new generation of total control is the Clever control. It leads the new generation of regulation with
maximum control that provides maximum energy efficiency. In addition, it allows you to visually monitor the air
quality and the status of the disinfection function. For more information request the Clever manual.
Fixings
The equipment has several external attachment points (see situation in the model characteristics section).
The anchor must be dimensioned according to the K7 weights indicated on the technical data page.
Installation can be done using threaded rods, turnbuckles or other supports. See available supports in the
accessories section.
Summary of Contents for K7 600 A OH+FC
Page 3: ...3 CONNECTION DIAGRAM ...
Page 4: ...4 ...
Page 9: ...9 ...
Page 10: ...10 ...
Page 11: ...11 ...
Page 12: ...12 DATASHEET ...
Page 13: ...13 ...
Page 21: ...21 DECLARATION OF CONFORMITY ...