17
Remove the motor by loosening the fixing screws. Assemble the replacement one following the process in
reverse order, making sure that the motor and turbine fit perfectly, the turbine screw must coincide with the flat
part of the motor shaft.
Remove with a screwdriver the side of the motor side.
(*) In case of the K7 600 A OH+FC SS, the motor connection must be disconnected in the IP55 waterproof box
located above the purifier.
Fuse replacement
Before doing any manipulations, warn and indicate that you are working, disconnect the power supply, make
sure that there is no voltage and that the fans have stopped.
For K7 600 A OH+FC and K7 600 A OH+FC CL, open the intake grille and remove the fuse by hand or the
help of a screwdriver and replace it.
In the case of the K7 600 A OH+FC SS, the board is inside the waterproof box above the purifier. Simply
unscrew the cap and remove the fuse by hand or the help of a screwdriver and replace it.