AirTechnic MAGI 11 User Manual Download Page 10

10

MAGI - 11 

&

 22

ΕΛ

EN

12. 

ΑΝΤΙΜΕΤΩΠΙΣΗ ΠΡΟΒΛΗΜΑΤΩΝ

12. 

TROUBLESHOOTING

N

o

Πρόβλημα / 

Problem

Αιτία / 

Cause

Λύση / 

Solution

1

Η μονάδα δεν εκκινεί

No discharge of air

Λανθασμένη ή 

αποσυνδεδεμένη παροχή 

ρεύματος

Incorrect or disconnected 

power supply

Βεβαιωθείτε ότι η μονάδα είναι σωστά 

συνδεδεμένη, η καλωδίωση δεν 

έχει υποστεί ζημιά & ότι η παροχή 

ρεύματος είναι εντός των απαιτήσεων 

της μονάδας.

Make sure the cooler is plugged in 

properly, the wiring is undamaged & 

the power supply is within the unit’s 

requirements.

Δυσλειτουργία χειριστηρίου

Controller malfunction

Αντικαταστήστε το χειριστήριο

Replace the controller

Δυσλειτουργία ηλεκτρικής 

ασφάλειας

Electrical fuse malfunction

Αντικαταστήστε την ασφάλεια

Replace the fuse

Δυσλειτουργία κεντρικής 

πλακέτας

Electrical mainboard

malfunction

Αντικαταστήστε την κεντρική πλακέτα

Replace the mainboard

2

Δεν υπάρχει ψύξη

No cooling

Η αντλία νερού δεν είναι 

ενεργοποιημένη

Water pump is not turned on

Ενεργοποιήστε την λειτουργία ψύξης

Turn on cool function

Βλάβη στην αντλία

Damaged pump

Αντικαταστήστε την αντλία

Replace the pump

Άδεια δεξαμενή /

χαμηλή στάθμη νερού

No water / low water

Επαναγεμίστε με νερό

Refill water

Δυσλειτουργία πλήκτρου του 

χειριστηρίου

The button on the controller 

is broken

Αντικαταστήστε το χειριστήριο

Replace the controller

Δυσλειτουργία κεντρικής 

πλακέτας

Electrical mainboard is 

broken

Αντικαταστήστε την κεντρική πλακέτα

Replace the mainboard

3

Δεν υπάρχει ροή άερα

No airflow

Δυσλειτουργία πλήκτρου του 

χειριστηρίου

The button on the controller 

is broken

Αντικαταστήστε το χειριστήριο

Replace the controller

Βλάβη κινητήρα

The motor is broken

Αντικαταστήστε τον κινητήρα

Replace the motor

4

Δυσάρεστη οσμή

Unpleasant odour

Βρώμικο νερό

Dirty water

Αποστραγγίστε τη δεξαμενή και

επαναγεμίστε με νερό

Drain and refill the water

Βρώμικη κυψέλη ψύξης

Dirty cooling pad

Καθαρίστε τη κυψέλη ψύξης

Clean the pad

Summary of Contents for MAGI 11

Page 1: ......

Page 2: ...wastes throughout the EU To prevent possible harm to the environment or the human health from uncontrolled waste disposal recycle it responsibly promoting the sustainable reuse of material resources...

Page 3: ...ed or function properly and damage may occur 6 Please disconnect the power supply from the cooler during rain 1 Thank you for your trust and support by choosing our Evaporative Air Cooler Please read...

Page 4: ...is damaged it must be replaced by the manufacturer an authorized agent or a qualified technician in order to avoid damaging the cooler 4 4 ATTENTION 1 Please open the side panel to check the parts an...

Page 5: ...se pay attention at the nothes of the tank during installation picture 2 picture 1 picture 2 6 6 GUIDE FOR REMOVING AND INSTALLING THE SIDE PANEL picture 3 picture 4 1 Remove the 8 screws using a cros...

Page 6: ...out the water funnel as shown in picture 5 2 Add water in the tank Drain Remove the valve cover to dump the water as shown in picture 6 Place the cover again when finished 8 8 MAIN CIRCUIT EN 7 7 GUID...

Page 7: ...te controller 9 9 INSPECTION BEFORE OPERATION 1 Place the assembled cooler on a level floor 2 Check if the draining pipe has been assembled 3 Check the water supply to be sure there is no leakage 4 Ve...

Page 8: ...r 30 sec and then switch back to the initial speed The process of speed change will not show on the LED screen 4 SWING function The SWING button will be lighted on when pressing it on the control pane...

Page 9: ...ding the manual when use the automatic cleaning function Alternatively take out the plug of drainage outlet and clean it manually 4 Maintenance a The cleaning frequency depends on the local air and wa...

Page 10: ...n Replace the fuse Electrical mainboard malfunction Replace the mainboard 2 No cooling Water pump is not turned on Turn on cool function Damaged pump Replace the pump No water low water Refill water T...

Page 11: ...100 685 30 x 200 x 50 Net weight 31 Dimensions 800 x 480 x 1 280 Operating weight 117 Water storage 75 A m3 h kW V Hz Kg dB A mm Pa L Kg mm mm 13 13 TECHNICAL PARAMETERS Notice 1 The above informatio...

Page 12: ......

Reviews: