AIRSTREAM CLASSIC TRAILER
REFRIGERATOR
Manufacturer:
Dometic Sales Corporation 2320
Industrial Parkway P.O. Box 490
Elkhart, Indiana 46514
igerator prior to
an absorption refrigerant system ammonia is liquefied in the finned condenser coil at the top rear of the
The tubing in the evaporator section is specifically sloped to provide a continuous movement of liquid
ammonia, flowing downward by gravity, through this section. If the refrigerator is operated out-of-level
when the vehicle is not moving, liquid ammonia will accumulate in portions of the evaporator tubing. This
will slow the circulation of hydrogen and ammonia gas, or in severe cases, completely block it, resulting in
a loss of cooling.
Any time the vehicle is parked for several hours with the refrigerator operating the vehicle should be
leveled to prevent this loss of cooling. The vehicle needs to be leveled only so it is
comfortable to live in
(no noticeable sloping of floor or walls).
When the vehicle is moving the leveling is not critical, as the rolling and pitching movement of the vehicle
will pass to either side of level, keeping the liquid ammonia from accumulating in the evaporator tubing.
OPERATION
The refrigerator requires 12-volt current to operate even if running on LP or 110 volt modes. The 12-volt is
used to power the circuit board that directs the refrigerator functions. When running in a mode such as LP,
it means the heat source, by far the largest power requirement; to evaporate the ammonia is being provided
by an LP Gas burner.
Phone: 219-295-5228
Review all Dometic Literature supplied in your Owner's Packet or stored in the refr
operating.
In
refrigerator. The liquid ammonia then flows into the evaporator (inside the freezer section) and is exposed
to a circulating flow of hydrogen gas, which causes the ammonia to evaporate, creating a cold condition in
the freezer.
WARNING
: Most LP gas appliances used in recreational vehicles are vented to the
outside of the vehicle. When parked close to a gasoline pump, it is possible that gasoline fumes could
enter this type of appliance and ignite the burner flame, CAUSING A FIRE OR AN EXPLOSION.
H-5
Summary of Contents for Classic Trailer 25' 2005
Page 1: ...AIRSTREAM AN AMERICAN LEGEND CLASSIC TRAILER OWNERS MANUAL 2005...
Page 2: ......
Page 14: ...AIRSTREAM CLASSIC TRAILER A 9 MAINTENANCE RECORD DATE DEALER SERVICE PERFORMED...
Page 15: ...AIRSTREAM CLASSIC TRAILER A 10 NOTES...
Page 33: ...AIRSTREAM CLASSIC TRAILER B 18 NOTES...
Page 39: ...AIRSTREAM CLASSIC TRAILER C 6 NOTES...
Page 58: ...AIRSTREAM CLASSIC TRAILER D 16 OTES N...
Page 72: ...AIRSTREAM CLASSIC TRAILER F 5 YPICAL GAS LINE SYSTEM T...
Page 113: ...AIRSTREAM CLASSIC TRAILER G 19...
Page 124: ...Notes...
Page 125: ......
Page 126: ......