ELECTRICAL
G - 12
G
G - 13
size hole. The Cat 5 wire is plugged into the display panel.
NOTICE
: The Yellow wire must be fused with a 10-amp in-line fuse at the
12-volt positive. All wires are identified with labels at all locations.
The solar panel has charge controller that should be mounted close to the
battery buss bars as the battery leads are hooked into it to sense the actual
battery charge. The Cat 5 wire plugs into it also.
This drawing is the way Airstream wires the system on factory installed units
and is the recommended wiring for use of the pre-wire system.
Solar Panel Pre-Wire
- All units are prewired with the yellow and green wires
only, located and labeled as stated above. The Cat5 cable is not included in
the pre-wire.
Cat Five
Patch Cable
10. Ga. Yellow
10. Ga. Yellow
10 Ga. Green
10 Ga. Green
10 amp Fuse
Battery
Battery
Solar Panel
10 Amp Inline Fuse within
12” of battery
Red/White
6 Ga. Red
6 Ga. Black
6 Ga. Red
12 Ga. Black
6 Ga. Black
12 Ga. Red
50 Amp Breaker
Battery Breaker
Buss bar
Yellow
Solar Panel
Display
GRD.
Ground Buss