Refer to the dimensional drawing and verify the consistency of 

 

*

the hole positions of the installation screws of the switch box to 

be installed in advance. (Fig. 4)

Terminal names

51 21 

Terminal names: Names of connection terminals inside 

 

the rear cover

Power supply cable 

through hole

Power supply 

cable connection 

terminal

Transmission cable 

through hole

Transmission cable 

connection terminals 

[TM201]

CN411

CN412

L

N

X1 X2

K1 K2 K1 K2

CH1

CH2

TRANSMISSION

EXTERNAL INPUT

[TM201]

VRF (

L

ON

W

ORKS

)

Transmission  

terminal

Screw Size : M3

Earth (Ground) 

terminal

Screw Size : M3

External input 

terminal

Screw Size : M3

Input method: 

pulse

POWER SUPPLY

Power supply 

terminal

1Ø 100-240V

Screw Size : M4

Earth (Ground) 

terminal

Screw Size : M4

External input function

51 31 

External input terminals:  

 

Function which uses external input terminals to perform 

the “Emergency stop” or “Batch start/batch stop” opera-

tion from the outside.
External input contact

 

CH1 and CH2 of TM201 of the rear cover are switched 

to "dry contact terminal" and "apply voltage terminal" by 

connecting CN201 on the front cover PCB to CN411 or 

CN412.

TM201- CH1, CH2

Connect with the CN201

Dry contact terminal

CN411 *

Apply voltage terminal

CN412

:Factory setting

 

*

Dry contact terminal

 

When a power supply is unnecessary at the input 

device you want to connect, connect CN201 and 

CN411.

Summary of Contents for UTY-DTGY

Page 1: ...H PANEL CONTROLLER CONTR LEUR DE PANNEAU CONTACT CONTROLADOR DE PANEL DE CONTACTO CONTROLADOR DE PAINEL DE TOQUE For authorized service personnel only Uniquement r serv aux techniciens agr s S lo para...

Page 2: ...o leak con tains suspended carbon fibers or flammable dust or volatile inflammables such as paint thinner or gaso line If gas leaks and settles around the unit it can cause a fire Do not use the unit...

Page 3: ...h ground the unit Transmission cable LONWORKS compatible cable External input cable Use cable in accordance with local rules for cable LONWORKS is registered trademark of Echelon Corporation in the Un...

Page 4: ...the screwdriver This will cause an accident The front cover and rear cover are connected by wir ing When disassembling be sure that the wiring is not stretched Do not touch this unit s circuit board...

Page 5: ...minals TM201 CN411 CN412 L N X1 X2 K1 K2 K1 K2 CH1 CH2 TRANSMISSION EXTERNAL INPUT TM201 VRF LONWORKS Transmission terminal Screw Size M3 Earth Ground terminal Screw Size M3 External input terminal Sc...

Page 6: ...nly CH1 can be used CH2 cannot be used Wiring 555555 WARNING Before starting installation work turn off the power of this unit and the connection destination Do not turn on the power again until insta...

Page 7: ...Remote controller Remote controller Remote controller Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Wire the transmission cable to any one of the following...

Page 8: ...E POWER 666 CAUTION Check that the power supply voltage is within the specified range If a power supply voltage outside the specification is input it will cause trouble Recheck the wiring Incorrect wi...

Reviews: