INSTALLATION MANUAL

INDOOR UNIT (Wall Mounted Type: EEV internal)

For authorized service personnel only.

PART NO. 9373370192

INSTALLATIONSANLEITUNG

INNENGERÄT (wandmontierter Typ: EEV intern)

Nur für autorisiertes Fachpersonal.

ASYA04GACH/ASHA04GACH
ASYA07GACH/ASHA07GACH
ASYA09GACH/ASHA09GACH
ASYA12GACH/ASHA12GACH
ASYA14GACH/ASHA14GACH

TM

MANUEL D’INSTALLATION

MANUAL DE INSTALACIÓN

APPAREIL INTÉRIEUR (Type montage mural : interne EEV)

UNIDAD INTERIOR (Tipo montado en pared: EEV interna)

Pour le personnel agréé uniquement.

Únicamente para personal de servicio autorizado.

MANUALE DI INSTALLAZIONE

UNITÀ INTERNA (tipo montato a parete: EEV interno)

A uso esclusivo del personale tecnico autorizzato.

ΕΓΧΕΙΡΙΔΙΟ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

ΕΣΩΤΕΡΙΚΗ

 

ΜΟΝΑΔΑ

 (

Επιτοίχιος

 

Τύπος

ΗΕΒ

 

εσωτερικά

)

Μόνο

 

για

 

εξουσιοδοτημένο

 

τεχνικό

 

προσωπικό

.

MANUAL DE INSTALAÇÃO

UNIDADE INTERIOR (Tipo mural: modelo interno com EEV)

Apenas para técnicos autorizados.

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

ВНУТРЕННИЙ

 

МОДУЛЬ

 (

настенного

 

типа

внутренний

 

электронный

 

расширительный

 

клапан

)

Только

 

для

 

авторизованного

 

обслуживающего

 

персонала

.

MONTAJ KILAVUZU

İ

Ç ÜN

İ

TE (Duvara Monteli Tip: EEV dahili)

Yaln

ı

zca yetkili servis personeli için.

English

Deutsch

Français

Español

Italiano

Ελληνικ

ά

Português

Ру

сский

Türkçe

9373370192_IM.indb   1

9373370192_IM.indb   1

2/16/2013   11:12:27 AM

2/16/2013   11:12:27 AM

Summary of Contents for ASHA04GACH

Page 1: ...NSTALACI N APPAREIL INT RIEUR Type montage mural interne EEV UNIDAD INTERIOR Tipo montado en pared EEV interna Pour le personnel agr uniquement nicamente para personal de servicio autorizado MANUALE D...

Page 2: ...It is recommended to use a gauge manifold with a high pressure display range 0 1 to 5 3 MPa and a low pressure display range 0 1 to 3 8 MPa Charging hose To increase pressure resistance the hose mate...

Page 3: ...inlet and outlet ports should not be obstructed the air should be able to blow all over the room 3 Leave the space required to service the air conditioner 4 A place from where the air can be distribu...

Page 4: ...juries If the job is done with the panel frame only there is a risk that the unit will come loose Please take care 3 3 1 Determining the piping direction The piping can be connected in the 5 direction...

Page 5: ...raising the upper surface and a front panel is removed Front panel 4 Insert the spacer etc between the indoor unit and the wall hook bracket and separate the bottom of the indoor unit from the wall Wa...

Page 6: ...rque wrench using the specified tightening method Otherwise the flare nuts could break after a prolonged period causing refrigerant to leak and generate hazardous gas if the refrigerant comes into con...

Page 7: ...arate these cable by 50 mm or more Bundling these cables together will cause miss operation or breakdown When handling PCB static electricity charged in the body may cause malfunction of the PCB Follo...

Page 8: ...en the terminal screws Do not use a screwdriver that is too small otherwise the screw heads may be damaged and prevent the screws from being properly tightened 4 Do not tighten the terminal screws too...

Page 9: ...7 0 7 7 0 7 8 0 8 8 0 8 9 0 9 9 0 9 10 1 0 10 0 0 11 1 1 11 1 1 12 1 2 12 1 2 99 9 9 63 6 3 Do not set the indoor unit address IU AD SW at 64 to 99 It may result in failure 6 FIELD SETTING There are...

Page 10: ...to 6 1 Setting the address for indoor unit address and refrigerant circuit address settings Turn the power of the indoor unit ON before starting the setting Turning on the power to the indoor units in...

Page 11: ...ion number ones place 0 5s ON 0 5s OFF FILTER indicator lamp Red Setting number 0 to 9 0 5s ON 0 5s OFF Example Function 31 Setting number 2 OPERATION indicator lamp Green TIMER indicator lamp Orange...

Page 12: ...side the indoor unit using a pull box etc as shown on below example DC power supply 12 to 24V connected unit Load resistance P C B P C B CNA01 P C B Input device 1 Input device 2 Indoor unit Indoor un...

Page 13: ...cted device 1 Connected device 2 Connected device 3 connected unit Relay Field supply Operation behavior Connector Output voltage Status CNB01 External output1 Pins 1 2 0V Stop DC 12 V Operation Exter...

Page 14: ...ng cover Screw Piping cover Screw Cable clamp Piping cover Screw 7 FINISHING CAUTION After checking for gas leaks refer to the Installation Manual of the outdoor unit perform this section Install heat...

Page 15: ...No operation After installation is completed has the proper operation and handling been explained to the user 10 ERROR CODES If you use a wired type remote controller error codes will appear on the re...

Reviews: