![Airspan AS4000 Installation And Commissioning Manual Download Page 119](http://html.mh-extra.com/html/airspan/as4000/as4000_installation-and-commissioning-manual_2879131119.webp)
AS4000 Subscriber Terminal
Installation and Commissioning
DLP 010
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 7 of 6
6.
To initiate the configuration click the left mouse button on
Configure ST.
8.
Viewing and Setting the Interface Data for Subscriber Terminals
working to a Demand Assigned Shelf
1.
This feature is not currently supported by STMON for windows and the
following message is displayed.
9.
R, S, and N series SIU programming using a test telephone.
1.
If STMON is unavailable the ST can be programmed using a test telephone.
Connect an MF or LD type telephone to the SIU
2.
Each SIU is initialised by entering a unique code. These codes are entered using
the telephone and should be provided by the RF planning office on a form
similar to that shown in Table 9.
Table 9. SIU Programming Information
Mode
DA=1
RF
3 digits
PN
1 digit
Identity
9 digits
Check N
o
.
1 digit
Remote site
location
1
0
0
6
1
000000000
7
CRU1
3.
Take phone off hook and key # * # using the DTMF keypad
4.
Enter Mode by keying 1 for DA or 2 for FA
5.
Enter RF code (3 digits)