Specifications
31
Transient response (full to
half load)
±
1% max. dev.
500 uS recovery
Temperature coeffeicient
±
0.04% /
°
C
Ripple and noise
100mVp-p max
Protections
Over voltage protection
(output voltage 7.5V)
Over power protection
Short circuit protection
Over current protection:
130% ˜ 160%
Efficiency
70% typical at full load
Hold-up time
5 ms @ 115 VAC full load
EMI / RFI
VDE and FCC Class B limits
Dielectric withstand
Input/output: 3000 Vac
Input/Ground: 1500 Vac
Safety meet
UL/CUL UL60950
CE EN55022
Switching frequency
100 kHz
Connector for radio
Input: interchangeable
prongs
Output: DC power jack
Cable length
1.25 m
Dimensions
86
×
46
×
33 mm
Weight
180 g
General
MTBF
100,000 hours (MIL-HDBK-217F)
Operating temperature
0 to +40
°
C
Storage temperature
-20 to +85
°
C
Humidity
5 to 95% RH non-condensing
Vibration
2.4G, 5 to 500 Hz
Environmental
Cooling
Free air convection