5 Install AirSynergy
Install the AirSynergy eNodeB by pole mount, wall mount, or single point. The AirSynergy unit
can be connected to various types of antennas via standard RF coaxial cables. Antennas should
be positioned with 10 wavelengths horizontal separation to give optimal Downlink and Uplink
MIMO performance.
AirSynergy is normally mounted on a pole (in close proximity to its external antenna when not
using the AirSynergy front mounted Antenna). Take care to install the mounting plate the correct
way up. This is with the slot openings in the bracket at the top edges as shown.
Caution:
Proper local rigging and hoisting practices should be followed when
installing the AirSynergy.
5.1 Pole Mount Assembly
The following images show the pole mount assembly.
1. Position mounting plate with slots facing up.
Figure 10 - AirSynergy mounting plate and hardware
2. Feed clamp bands through the quick release locking mechanisms and wrap around pole.
Figure 11 - Assemble clamp bands (2 required)
3. Wrap the band to properly fit on the pole. Press down locking mechanism with band
excess fed through the mechanism.