AirSpeed 1050 Installation Guide
DUG01545
Airspan Commercial and Internal Use
25
5 Connect and Manage Cables
5.1 Connecting the Ground Cable
Connect the ground lug with the ground cable (not supplied) to the M6 threaded bolt on the bracket
assembled on the unit clearly marked with the universal ground symbol.
Note:
Cutting the ground cable to the required length and crimping the grounding lug is performed
by the Installer.
The cable should be grounded according to international or local standards.
Figure 11: Ground Connection
5.2 Cable Connection
The following explains the general instructions on how to connect a power cable (DC & AC) and the
SFP & Copper Ethernet cables to the AirSpeed 1050 unit.
Danger:
Hazardous voltage!
Before working, ensure that the power is removed from the power
connection cables. When the system is powered on,
do not touch the power terminals
.
Airspan recommends the following outdoor Power cable requirements – Cable, 3C, SJOOW, 18AWG,
Stranded, Outdoor.
Table 8: Outdoor Power Cable Requirements
Outdoor Power Cable
18 AWG
Jacket 300V
Water Resistant
UV Resistant